본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

Korean Journal of Chemical Engineering , 2007년, pp.1128 - 1132  
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

Development of a pilot-scale acid gas removal system for coal syngas
Development of a pilot-scale acid gas removal system for coal syngas

Seung Jong Lee  Soung Hyoun Kim  Kyoung Hoon Kang  Young Don Yoo  Yongseung Yun 
  • 초록

    Korean pilot-scale gasification facility consists of a coal gasifier, hot gas filtering system, and acidgas removal (AGR) system. The syngas stream from the coal gasification at the rate of 100-120 Nm3/hr included pol-lutants such as fly ash, H2S, COS, etc. The acid gas, such as H2S and COS, is removed in the AGR system before gen-erating electricity by gas engine and producing chemicals like Di-methyl Ether (DME) in the catalytic reactor. A hy-drolysis system was installed to hydrolyze COS into H2S. The designed operation temperature and pressure of the COShydrolysis system are 150oC and 8 kg/cm2operating condition. The normal designed operation temperature and pressure of the AGR system are below 40oC and8kg/cm2. Fe-chelate was used as an absorbent. H2S was removed below 0.5 pm in the AGR system when the max-imum concentration of H2S was 900 pm. A small scale COS adsorber was also installed and tested to remove COSbelow 0.5 ppm. COS was removed below 0.1 ppm after the COS adsorbents such as the activated carbon and ion ex-change resin.


 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.
유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.