  • 초록

    Purpose : To evaluate the utomated 1H magnetic resonance spectroscopy (1H-MRS) method for a routine clinicaluse, various regions of the normal human brain were examined for regional variations, the reproducibility, and thequality control of the spectral data. Materials and Methods : Localized 1H-MRS was performed in a GE 1.5T SIGNAMRI/MRS system using the automated method(PROton brain Exam : PROBE). Six regions of the human brain from normalvolunteers (N=25, age=23-65) were examined : Occipital gray matter, parietal white matter, frontal white matter,pons, cerebellum, and basal ganglia regions. STEAM was used as the localization method with the followingparameters : TE=30 msec, TR=3.0 sec, AVG=48 AVG, NEX=2, Spectral Width (SW)=2500 Hz, Size (SI)=2048 points (2K),and the size of voxel=7-9 ml, The reproducibility and the quality control of the spectral date were evaluated.Results : For the 6 regions, the regional variation by the spectral patterns and the metabolites ratios relativeto creatine was well demonstrated. Rates of the auto prescan success and the percentages of obtaining theacceptable quality spectra were high in the parietal white matter, occipital gray matter, and basal gangliaregions, and low in the frontal white matter and pons regions. Conclusion : PROBE is a highly practical as well asreliable method to produce reproducible quality spectra that represent the regional metabolic variations in thehuman brain, PROBE can be used as a single spectroscopic exam or as an additional series to a routine brain MRIexam, which takes less than 10 minutes for acquiaition of one spectrum. In order to obtain good quality spectra, agood quality control scheme of the MR instrument is mandatory.


  • 주제어

    Magnetic resonance(MR), spectroscopy.  

  • 참고문헌 (16)

    1. Added value of automated clinical proton MR spectroscopy of the brain , Moast RA;Watson L;Shonk T;Tokuyama S;Braslau D;Eto R;Mandigo JC;Ross BD , J Comput Assist Tomogr / v.19,pp.480-491,
    2. Metabolic disorders of the brain in chronic hepatic encephalopathy detected with ¹HMRS , Kreise R;Ross BD;Farrow NA;Ackerman Z , Radiology / v.182,pp.19-27,
    3. Highly effective water suppression for in vivo proton NMR spectroscopy (DRY STEAM) , Moonen CTW;van Zijl PCM , J Magn Reson / v.88,pp.28-41,
    4. ¹H NMR chemical shift selective(CHESS)imaging , Haase A;Frahm J;Hanicke W;Mattaei , PhysMedBiol / v.30,pp.,
    5. Water signal elimination in vivo, using suppression by mistimed echo and repetitive gradient episodes , Doddrell DM;Galloway G;Brooks W;Filed J;Bulsing J;Irving M;Baddeley H , J Magn Reson / v.70,pp.176-180,
    6. BrefReport:Organic osmolytes in the brain of an infant with hypernatremia , Lee JH;Arcinue E;Ross BD , N Eng J Med / v.331,pp.439-442,
    7. Localized porton spectroscopy using stimulated echoes , Frahm J;Merboldt K;Hanicke W , J Magn Reson / v.72,pp.502-508,
    8. Subclinical hepatic encephalopathy:Proton MR spectroscopic abnormalities , Ross BD;Jacobson S;Vilamil F;korula J;Kreis R;Ernst T;Shonk T;Moats R , Radiology / v.193,pp.457-463,
    9. Temporal lobe epilepsy:presurgical localization with proton chemical shiftimaging , Ng TC;Comair YG;Xue M;So M;Majors A;Kolem H;Luders H;Modic M , Radiology / v.193,pp.465-472,
    10. Clinical applications of magnetic resonance spectroscopy , Ross B;Michaelis T , Magn Reson Q / v.10,pp.191-247,
    11. Volume selective multipulse spin-echo spectroscopy , Kimmich R;Hoepfel D , J Magn Reson / v.70,pp.488-192,
    12. Development of the human brain:in vivo quantification of metabolite and water content with proton magnetic resonance spectroscopy , Kreise R;ernst T;Ross BD , Magn Reson Med / v.30,pp.1-14,
    13. Proton magnetic resonance spectroscopy:a diagnostic tool for probable Alzheimer disease , Shonk TK;Moasts RA;Gifford P(et al) , Radiology(in press) / v.,pp.,
    14. Quality control in volume selective spectroscopy , Schenker KV , The 1st Symposium on Magnetic Resonance Applied to Psychiatry / v.,pp.,
    15. Clinical tools for the 90's:magnetic resonance spectroscopy and metabolite imaging , Ross BD;Kreise R;ernst T , Eur J Radiol / v.14,pp.128-140,
    16. Automated single-voxel proton MRS:technical development and multisite verification , Webb PG;Sailasuta N;Kohler SJ;Raidy T;Moats RA;Hurd RE , Magn Reson Med / v.31,pp.365-373,

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.
유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기