본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

부위별 생체 전기 임피던스법을 이용한 체성분 분석에 관한 연구
Segmental Bioelectrical Impedance Analysis(SBIA) for Determining Body Composition

차기철    (주식회사 바이오스페이스 생체공학 연구소   ); 손정민    (서울대학교병원 급식영양과   ); 김기진    (계명대학교 체육학과   ); 최승훈    (연세대학교 의과대학 외과학교실  );
  • 초록

    A new bioelectrical impedance method has been developed and evaluated. The electrodes; were made of stainless steel and electrical interfaces were created by an upright subject gripping hand electrodes and stepping onto foot electrodes. Eight tactile electrodes were in contact with surfaces of both hands and feet; thumb, palm and fingers, front sole, and rear sole. Automatic on-off switches were used to change current pathways and to measure voltage differences for target segments. Segmental body resistances and whole body resistance(RWHOLE)were measured in 60 healthy subjects. Segmental resistances of right arm(RRA), left arm(RLA), trunk(RT), right leg(RRL) and left leg(RLL)were310.0 $\pm$ 61.6 $\Omega$ , 316.9 $\pm$ 64.6 $\Omega$ , 25.1 $\pm$ 3.4 $\Omega$ , 236.8 $\pm$ 31.2 $\Omega$ and 237.6 $\pm$ 30.4 $\Omega$ , respectively. Individual segmental impedance indexes(Ht2/RRA, Ht2/RT, and Ht2 /RLA) were closely related to lean body mass(LBM)as measured by densitometry ranged from r=0.925 to 0.960. Ht2/(RRA+RT+RLA) predicted LBM slightly better(r=0.969) than the traditional index, Ht2/RWHOLE(r=0.964), supporting the accuracy of the segmental measurement. A multiple regression equation utilizing Ht2/RRA, Ht2/RT and Ht2/RRL predicted LBM with r=0.971. Ht2/RRA term of the regression contributed to more than 40 $\%$ of the LBM prediction, indicating that lean mass of arm represented whole body LBM more closely than other body segments. The new bioimpedance method was characterized by upright posture, eight tactile electrodes, segmental measurements and utilization of electronic switches in comparison with the traditional method. The measurement with this new method was extremely reproducible, quick and easy to use.


  • 주제어

    segmental bioelectrical impedance analysis(SBIA) .   lean body mass(LBM) .   Body Fat.  

 저자의 다른 논문

  • 차기철 (1)

    1. 2001 "생체 임피던스 측정 방법을 한국인의 연령층별 체성분 분석에 관한 연구" 대한영양사회 학술지 = Journal of the Korean dietetic association 7 (2): 153~158    
  • 김기진 (6)

  • 최승훈 (25)

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • NDSL :
유료다운로드

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 이용한 콘텐츠
이 논문과 함께 출판된 논문 + 더보기