본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

저작압이 임프란트 주위골 내 응력분포에 미치는 영향에 관한 연구
AN ANALYSIS OF STRESS DISTRIBUTION AROUND THE IMPLANT ACCORDING TO THE BONE QUALITY AND BITE FORCE: FINITE ELEMENT METHOD

현기봉   (서울대학교 치과대학 치과보철학교실UU0000691  ); 이선형   (서울대학교 치과대학 치과보철학교실UU0000691  ); 장익태   (서울대학교 치과대학 치과보철학교실UU0000691  ); 양재호   (서울대학교 치과대학 치과보철학교실UU0000691  ); 신상완   (고려대학교 의과대학 치과학교실 (구로병원)UU0000159  );
  • 초록

    Since the early study about the osseointegration, lots of researches have been performed to increase the success rate and the stress around the implant in the jaw bone has been considered as one of the causes of failure. The purpose of this study was to examine the relationship between the implant failure and the stress by analysing the influence of different bone quality and bite force of some foods on the stress distribution around the implant, and to estimate the treatment result according to the bone quality and dietary pattern of patients. Bone quality was divided in 4 groups and models were drawn with the assumption that thread type implant(Nobel Biocare AB, Goteborg, Sweden) of 3.75mm diameter, 13mm length was installed to the bones. Various bite forces were applied to the occlusal surface of superstructure and the stress distributed around the implant were analysed with finite element analysis program. The results were as follows ; 1. The stress was changed proportionally to the bite forces of foods at all measuring points in all load cases. 2. The stress at the marginal bone was higher than that of the other measuring points in all load cases, and it was decreased at the first thread area. 3. The stress at the marginal bone was highest in type IV bone in all load cases. Especially it was twice those of other bone types at the bucco-lingual marginal bone and 50% higher at the mesio-distal marginal bone. 4. The stress at the bucco-lingual sides of the bone around the apical portions of implant showed little differences among the bone types, while type IV bone showed lower stress concentration than the other bone types in the mesio-distal sides. 5. Under the buccal oblique load ( $15^{\circ}$ ), the stress at the lingual marginal bone was higher than that of buccal marginal bone, and the difference between the two points was almost same regardless of bone types.


  • 주제어

    Implant .   Bone quality .   Bite force .   Finite element .   Stress.  

 저자의 다른 논문

  • 이선형 (75)

    1. 1968 "열(熱)에 대(對)한 치수반응(齒髓反應)" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 8 (1): 124~126    
    2. 1976 "치근단절제술 실패의 일례" 大韓齒科醫師協會誌 = The journal of the Korean dental association 14 (5): 457~459    
    3. 1976 "치과용 씨멘트에 대한 치수반응" 大韓齒科醫師協會誌 = The journal of the Korean dental association 14 (8): 659~663    
    4. 1976 "ASC52 attchment 이용한 하악편측 유리단 회복의 일례" 大韓齒科醫師協會誌 = The journal of the Korean dental association 14 (4): 377~379    
    5. 1977 "금합금과 도재소부전장주조관용 비금속합금간의 납착에 관한 연구" 大韓齒科醫師協會誌 = The journal of the Korean dental association 15 (12): 969~974    
    6. 1978 "주조용 귀금속합금과 비금속합금간 납착부의 인장강도" 大韓齒科醫師協會誌 = The journal of the Korean dental association 16 (12): 953~955    
    7. 1981 "한국산(韓國産) 치과주조용(齒科鑄造用) 저금함유합금(低金含有合金)의 조성(組成) 및 기계적(機械的) 성질(性質)에 관(關)한 비교연구(比較硏究)" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 19 (1): 17~27    
    8. 1981 "만성 하악관절염과 저작근 기능장애의 치료" 大韓齒科醫師協會誌 = The journal of the Korean dental association 19 (11): 901~905    
    9. 1982 "도재전장금관의 심미성에 대하여" 大韓齒科醫師協會誌 = The journal of the Korean dental association 20 (2): 127~130    
    10. 1983 "고무 인상재의 정확도에 관한 연구" 大韓齒科醫師協會誌 = The journal of the Korean dental association 21 (3): 237~243    
  • 장익태 (84)

  • 양재호 (141)

  • 신상완 (64)

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기