공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구
A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS

박철   (단국대학교 치과대학 보철학교실UU0000336  ); 임주환   (단국대학교 치과대학 보철학교실UU0000336  ); 조인호   (단국대학교 치과대학 보철학교실UU0000336  ); 임헌송   (단국대학교 치과대학 보철학교실UU0000336  );
  • 초록

    Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$ , Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p $Periotest^{(R)}$ . There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p


  • 주제어

    Non-invasive .   Resonance frequency .   Resonance frequency Analyser.  

  • 참고문헌 (51)

    1. Albrektsson T, Jacobsson M. Bonemetal interface in osseoi- ntegration. J Prosthet Dent 1987;57:597 
    2. Meredith N, Rasmussen L, Sennerby L. Alleyne D. Mapping implant stability by resonance frequency analysis. Med Sci. Research 1996;24:191 
    3. Measurement of Vibration & Frequency 30 analysis International Industiral Information system. 1989 
    4. Singiresu S R. Determination of natural frequency & mode shape. Mechanical vibration 1986:322 
    5. Cawley P, Adams RD. The mechanics of the coin-tap method of non-destructive testing. J Sound Vibration 1988:122(2):299 
    6. Johansson CB, Strid KG. Assessment of bone quality from cutting resistance during implant surgery. Int J Oral Maxillofac Implants 1994:9:279 
    7. Brunski JB. Biomaterials and biomechanics in dental implant design. Int Oral Maxillofac Implants 1988:3:85 
    8. Brunski JB, Mocclia Jr AF, Pollack SR. The influence of functional use of endosseous dental implants on the tissue-implant interface. I Histological aspects. J Dent Res 1979;10:58 
    9. Carr AB, Larsen PE, Papazoglou E, McGlumphy. Reverse torque failure of screw-shaped implants in babbons : Baseline data for abutment torque application. Int J Oral Maxillofac Implants 1995;10:167 
    10. Sennerby L. Thomsen P. Ericson LE. Early tissue response to titanium implants inserted in rabbit cortical bone. Part 2 Ultrastructural observations. J Mater Sci. : Mater in Med 1993;4:494 
    11. Wennerberg A. On surface roughness and implant incorporation. Ph.D. Thesis. Department of Biomaterials/Handicap Research, Institute for Surgical Sciences, and Department of Prosthetic Dentistry. Gothenburg Universith, Gothenburg, Sweden. 1996 
    12. Branemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399 
    13. Bruel and Kjaer : Model Analysis 1992 
    14. Friberg B, Sennerby L, Roos J, Strid CG, Lekholm U. Evaluation of bone density using cutting resistance measurements and microradiography : an in vitro study in pig ribs. Clin Oral Impl Res 1995(b):6:164 
    15. Chavez H, Lance FO. Assessment of oral implant mobility. J Prosthet Dent 1994;70:421 
    16. Handbook of Noise & Vibration : The Korean Society for Noise & Vibration Engineers. 1995;221 
    17. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequecny analysis : Clin Oral Impl Res 1996:7:261 
    18. Albrektsson T, Zarb GA, Worthington P, Eriksson AR. The long term efficacy of currently used dental implants : A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11 
    19. van Steenberghe D, Tricio J, Nys A. Damping characteristics of bone to implant interfaces. Clin Oral Impl Res 1995;6:31 
    20. Rice JC, Cowin SC, Bowman JA. On the dependence of the elasticity and strength and of cancellous bone on apparent density. J Biomech 1988;21:155 
    21. Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. Clin Oral Implant Research 1997:226 
    22. Derhami K, Wolfaardt JF. Dent M, Faulkner G. Grace M. Assessment of the periotest device in base line mobility measurements of craniofacial implants. Int J oral Maxillofac Implants 1995;10:221 
    23. Ashman RB. Ultrasonic determination of the elastic properties of cortical bone : techniques and limitations 'Thesis'. New Orleans, LA : Tulane University, 1982 
    24. Brunski JB, Mocclia Jr AF, Pollack SR, Korostoff E, Trachtenberg D. Investigation of surfaces of retrieved endosseous dental implants of commercially pure titanium. American Society for Testing and Materials. 1983;189 
    25. Tsuboi Y, Sennerby L, Mori K, Matsuhisa H. The dynamic of the osseointegrated implant. Part 1: Theoretical analysis of the osseointegrated implant and the natural tooth by the vibration theory. Personal Communication. 1996 
    26. Hobo S, Ichida E, Garcia LT. Osseointegration and occlusal rehabilitation. Chicago. Quintessence Publ Co. 1989;265 
    27. Lekholm U, Zarb GA. Patient selection and preparation. In Osseointegration in clinical dentistry (Branemark PI, Zarb G, Albrektsson T, eds). Quintessence Co. Chicago. 1985;199 
    28. Albrektsson T, Sennerby L. State of the art in oral implants. J Clin Periodontol 1991;18:474 
    29. Shulte W. A new field of application of the Periotest mathod. The occlusal-periodontal load can now be measured quantitatively. Zahnarztl Mitt. 1988:78:474 
    30. Albrektsson T. Bone tissue response. In Osseointegration in clinical dentistry. Quintessence Co. Chicago 1985;129 
    31. Elias JJ. Brunski JB, Scarton HA. A dynamic modal testing technique for non-invasive assessment of bone-dental implant interface. Int J Oral Maxillofac Implants 1996:11:728 
    32. Branemark PI, Zarb GA, Albrektsson T. Tissue integrated prosthesis : Osseointegration in clinical dentistry, Chicago, Quintenssence Co, 1985;117 
    33. Meredith N. On the clinical measurement of implant stability and osseointegration. Ph.D. Thesis, Department of Biomaterials / Handicap Research, Institude for Surgical Sciences. Gothenburg University, Gothenburg. Sweden. 1997 
    34. Johansson CB, Sennerby L, Albrektsson T. A removal torque and histomorphometric study of bone tissue reactions to commercially pure titanium and vitallium implants. J Oral Maxillofac Implants B 1991;437 
    35. Chavez H, Lance FO. Assessment of oral implant mobility. J Prosthet Dent 70 1994;421 
    36. Cucchario PJ, DeLuzio A, Dario LJ, Cucchario SJ. Structural analyser in particular for medical implants. United States Patent No. 1996;5:518 
    37. Shulte W. The Periotest periodeontal status. Zahnarztl Mitt. 1986:76:1 
    38. Tricio J, van Steenberghe D, Rosenberg D, Duchateau L. Implant stability related to insertion torque force and bone density: An in vitro study. J Prosthet Dent 1995;74:608 
    39. Johansson CB, Albrektsson T. A removal torque and histomorphometric study of commercial pure nobium and titanium implants in rabbit bone. Clin Oral Impl Res 1991;2:24 
    40. Friberg B. Bone quality evaluation during implant placement. MDS dissertation, University of Gothenburg, Gothenburg, Sweden, 1994 
    41. Johanson CB, Albrektsson T. Integration of screw implants in the rabbits : A 1-yrfollow-up of removal torque of titanium implants. Int J Oral Maxillofac Implants 1987;2:69 
    42. Roos J, Sennerby L, Albrektsson T. An update on the clinical documentation on currently used bone anchored endosseous oral implants. Dent Update in press 1997 
    43. Friberg B, Sennerby L, Roos J, Lekholm U. Identification of bone quality in conjunction with insertion of titanium implants. Clinical Oral Implant Research 1995(a);13:213 
    44. Branemark PI. Hansson BO. Osseointegrated implants in the treatment of the edentulous jaw. Distributed by the Almquist and Wiksell periodical Co 
    45. Theories Practices of Vibration Samsung Institute of Technology of Electon particle. 1991:1 
    46. Lim JH, Cho IH : A study on the evaluation of Bone quality of Maxillo and Mandibule by using peroitest. 1994;32:7.520 
    47. Albrektsson T, Branemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants. Acta Orthop Scand 1981;52:155 
    48. Strid JG. Radiographic results. In osseointegration in clinical dentistry (Branemark PI, Zarb G, Albrektsson T. eds) Quintessence Publiahers, Chicago. 1985;187 
    49. Sennerby L., Thomsen P, Ericson LE. Early tissue response to titanium implants inserted in rabbit cortical bone. Part 1 Light microscopic observations. J Mater Sci. : Mater in Med 1993;4:240 
    50. Branemark PI. A biomechanical study of osseointegration. Ph.D thesis. Department of Orthopaedics. Institute of Surgical Science and Institute of Anatomy and Cell Biology, University of Gothenburg, Gothenburg, 1996 
    51. Deutch JE, Brunski JB. Numerical analysis of load distribution among dental implants. AADR Meeting, San Francisco, Calif. 1989:Paper No. 587 
  • 이 논문을 인용한 문헌 (3)

    1. 2006. "" 대한치과보철학회지 = The journal of Korean academy of prosthodontics, 44(3): 314~324     
    2. Lee, Ju-Hyon ; Min, Hyun-Gi ; Lee, Jin-Sook ; Kim, Myung-Rae ; Kang, Na-Ra 2008. "RESONANCE FREQUENCY ANALYSIS IN NON-SUBMERGED, INTERNAL TYPE IMPLANT WITH SINUS AUGMENTATION USING DEPROTEINIZED BOVINE BONE MINERAL" 대한악안면성형재건외과학회지 = The journal of Korean association of maxillogacial plastic and reconstructive surgeons, 30(6): 554~560     
    3. Kim, Sung-Won ; Cho, In-Ho 2014. "On the osseointegration of zirconia and titanium implants installed at defect site filled with xenograft material" 대한치과보철학회지 = The journal of Korean academy of prosthodontics, 52(1): 9~17     

 저자의 다른 논문

  • 박철 (1)

    1. 2000 "독립된 결합조직 이식술로 치은퇴축 치료시 치근 피개에 관한 임상적 연구" 대한치주과학회지 = The journal of Korean academy of periodontology 30 (3): 651~661    
  • 임주환 (44)

  • 조인호 (121)

  • 임헌송 (20)

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 이용한 콘텐츠
이 논문과 함께 출판된 논문 + 더보기