A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS

Park Chan-Jin    (Department of Prosthodontics, College of Dentistry, Kangnung National University   ); Kim Yung-Soo    (Department of Prosthodontics, Graduate School, Seoul National University   ); Kim Chang-Whe    (Department of Prosthodontics, Graduate School, Seoul National University   ); Cho Lee-Ra    (Department of Prosthodontics, College of Dentistry, Kangnung National University   ); Yi Yang-Jin    (Department of Prosthodontics, College of Dentistry, Kangnung National University  );
  • 초록

    Statement of problem: Resonance frequency analysis (RFA) has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized baseline data using RFA. Purpose: This study was performed to evaluate RFA value changes in two stage surgery group and one stage surgery group in patients. Material and method: Forty-seven mandibles in consecutively implant installed patients were selected for this study and 141 fixtures were installed. Ninety-three fixtures were double threaded, machined surface design ( $Br{\aa}anemark^{(R)}$ MK III, Nobel Biocare AB, Goteborg, Sweden) and 48 fixtures were root form, threaded, HA-coated surface one ( $Replace^{TM}$ , Steri-Oss/Nobel Biocare AB, USA). Among those, each 10 fixture was installed in one stage group patients. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, at healing abutment connection and in the loading period for two stage surgery group patients and during at each 4, 6, 8, 10, 12week and in the loading phase for one stage surgery group patients and evaluated the changes according to the time and fixture type. Results: In two stage surgery group, mean and SO of ISQ values of machined surface implants were $76.85{\pm}3.74,\;75.76{\pm}5.04,\;75.73{\pm}4.41$ and those of HA-coated surface implant were $75.05{\pm}6.23,\;77.58{\pm}5.23,\;78.32{\pm}4.29$ during fixtures installation, at healing abutment connection and in the loading period, respectively. In one-stage surgery group, the ISQ values of machined surface and HA-coated surface implants decreased until 4 or 6 week and maintained at plateau for 1-3 week and increased to the loading period. Conclusions: Machined and HA-coated surface implants showed minimal ISQ changes with time if they were installed at the sites showing at least intact cortical plate and good bone qualities. And HA-coated implants had a tendency to show somewhat increased ISQ values with time.


  • 주제어

    Implant stability .   Resonance frequency analysis (RFA) .   Machined surface .   HA-coated surface .   Two stage surgery .   One stage surgery.  

  • 참고문헌 (32)

    1. Park C. A study of the measurement of the implant stability using resonance requency analysis. PhD thesis, 2000, Dankook University, Korea 
    2. Lekholm U, Zarb GA. Patient selection and preparation, in Branemark PI, Zarb GA, Albrektsson T.(eds): Tissue-Integrated Prostheses : Osseointegration in Clinical Dentistry. Chicago:Quintessence, 1985:199-209 
    3. Sennerby L, Friberg B, Linden B, Jemt T, Meredith N. A comparison of implant stability in mandibular and maxillary bone using RFA. European Commission Demonstration Project. Resonance Frequency Analysis Symposium. 2000, Gothenburg, Sweden 
    4. Friberg B, Sennerby L, Roos J, Johansson P, Strid CG, Lekholm U. Evaluation of bone density using cutting resistance measurements and microradiography. : An in vitro study in pig ribs. Clin Oral Impl Res 1995;6:164-171 
    5. Park CJ. In vitro comparative study between ISQ and Peritcst $^\circledR$ values on the implant stability measurements according to the increased effective implant length. J Korean Academy of Prosthodontics 2001;39:625-635 
    6. Toljanic J, Banakis M, Willes L, Graham L. Soft tissue exposure of endosseous implants between stage I and stage II surgery as a potential indicator of early crestal bone loss. Int J Oral Maxillofac Impl 1999;14:436-441 
    7. Albrektsson T, Branemark PI, Hansson H, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a longlasting direct boneto- implant anchorage in man. Acta Orthop Scan 1981;52:155-170 
    8. Tal H, Dayan D. Spontaneous early exposure of submerged implants: III. Histopathology of perforated mucosa covering submerged implants. J Periodontol 2000;71:1231-1235 
    9. Al-Nawas B, Groetz KA, Brahm R, Wagner W. Resonance-frequency-analysis in the healing and loading period of dental implants. IADR abstracts 2002;1027 
    10. Ericsson I, Rainbow K, Nilner K, Petersson A. Some clinical and radiographical features of submerged and non-submerged titanium implants. A 5-year follow-up study. Clin Oral Impl Res 1997;8:422-426 
    11. Friberg B. On bone quality and implant stability measurements. PhD thesis. 1994, University of Gothenburg, Sweden 
    12. Friberg B, Sennerby L, Linden B, Grondahl K, Lekholm U. Stability measurements of one-stage Br${\aa}$nemark implants during healing in mandibles. A clinical resonance frequency study. Int J Oral Maxillofac Surg 1999b;28:266-272 
    13. Adell R, Lekholm U, RockIer B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416 
    14. Albrektsson T, Sennerby L. State of the art in oral implants. J Clin Periodontol 1991;18:474-481 
    15. $Osstell^{TM}$ resonance frequency analyser. Clinical Manual. Integration Diagnostics Ltd. S$\"{a}$vedalen, Sweden. 2002 
    16. Johansson P, Strid KG. Assessment of bone quality from cutting resistance during implant surgery. Int J Oral Maxillofac Impl 1994;9:279-288 
    17. Meredith N. Assessment of implant stability as a prognotic determinant. Int J Prosthodont 1998;11:491-501 
    18. Meredith N, Sagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurement to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Impl Res 1997;8:234-243 
    19. Park CJ. Stability measurement on the implants of mandibular molar area using $Osstell^{TM}$. J Korean Academy of Stomatognathic Function and Occlusion 2001;17:205-211 
    20. Ericsson I, Rainbow K, Glantz PO, Lindhe J, Nilner K. Clinical and radiographical features of submerged and nonsubmerged titanium implants. Clin Oral Impl Res 1994;5:185-189 
    21. Friberg B, Sennerby L, Roos J, Lekholm U. Identification of bone quality in conjunction with insertion of titanium implants. Clin Oral Impl Res 1995;6:213-219 
    22. Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofacial Surg 1999a;28:297-303 
    23. Buser D, Mericske-Stern R, Bernard JP. Longterm evaluation of non-submerged ITI implants. Part 1:8-year life table analysis of a prospective multicenter study with 2359 implants. Clin Oral Impl Res 1997;8:161-172 
    24. Tal H. Spontaneous early exposure of submerged implants: I. Classification and clinical observations. J Periodontol 1999;70:213-219 
    25. Tal H, Dayan D. Spontaneous early exposure of submerged implants: II. Histopathology and histomorphometry of non-perforated mucosa covering submerged implants. J Periodontol 2000;71:1224-1230 
    26. Sennerby L, Meredith N. Resonance Frequency Analysis: Measuring implant stability and osseointegration. Compendium 1998;19:493-502 
    27. Buser D, Weber HP, Bragger U, Balsiger C. Tissue integration of one-stagem implants :3-year results of a longitudinal study with hollow-cylinder and hollow-screw implants. Int J Oral Maxillofac Impl 1991;6:405-412 
    28. Becker W, Becker B, Isarelson H. One-step surgical placement of Branemark implants: A prospective multicenter clinical study. Int J Oral Maxillofac Impl 1997;12:454-462 
    29. Meredith N. On the clinical measurement of implant stability and osseointegration. PhD thesis, 1997, University of Gothenburg, Sweden 
    30. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Impl Res 1996;7:261-267 
    31. Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in-vivo: A cross sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Impl Res 1997;8:226-233 
    32. Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated implants. A review of the literature. Int J Prosthodont 1998;11:408-420 
  • 이 논문을 인용한 문헌 (3)

    1. 2004. "" 대한치과보철학회지 = The journal of Korean academy of prosthodontics, 42(6): 671~678     
    2. Kim Sun-Jong ; Shin Sang-Wan ; Jung Sung-Min ; Ryu Jae-Jun 2005. "A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS" 대한치과보철학회지 = The journal of Korean academy of prosthodontics, 43(1): 78~94     
    3. Choi, Jeong-Hun ; Lee, Ju-Min ; Kim, Yong-Deok ; Shin, Sang-Hun ; Chung, In-Kyo 2010. "ASSESSMENT OF BONE DENSITY ON MAXILLA AFTER IMPLANTATION WITH CONE BEAM COMPUTED TOMOGRAPHY" 대한악안면성형재건외과학회지 = The journal of Korean association of maxillogacial plastic and reconstructive surgeons, 32(3): 229~235     

 저자의 다른 논문

  • 김영수 (111)

    1. 1968 "총의치(總義齒) 장착환자(裝着患者)의 연하역치(?下?値) 관(關)한 실험적(實驗的) 연구(硏究)" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 8 (1): 77~79    
    2. 1968 "치과용(齒科用) Cement하(下)에서의 Liner의 작용(作用)에 관(關)한 실험적(實驗的) 연구(硏究)" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 8 (1): 90~94    
    3. 1969 "인공저작압(人工咀嚼壓)에 관(關) 실험적(實驗的) 연구(硏究)" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 9 (1): 63~68    
    4. 1969 "의치인상채득(義齒印象採得)에 관련(關聯)되는 응용물리학(應用物理學)" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 9 (1): 79~83    
    5. 1970 "의치의 복제" 大韓齒科醫師協會誌 = The journal of the Korean dental association 8 (5): 429~432    
    6. 1970 "Removable appliance를 장착할 때에 당면하는 난점들(2)" 大韓齒科醫師協會誌 = The journal of the Korean dental association 8 (7): 474~476    
    7. 1970 "전기도금에 의한 총의치의 금속구개상 제작" 大韓齒科醫師協會誌 = The journal of the Korean dental association 8 (10): 560~564    
    8. 1970 "Removable appliance를 장착할 때에 당면하는 난점들(1)" 大韓齒科醫師協會誌 = The journal of the Korean dental association 8 (6): 477~480    
    9. 1970 "무치악환자에 대한 압박인상 변법" 大韓齒科醫師協會誌 = The journal of the Korean dental association 8 (6): 485~486    
    10. 1970 "보철과 Tooth Mobility" 大韓齒科醫師協會誌 = The journal of the Korean dental association 8 (9): 513~518    
  • 김창회 (88)

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기