냉각식 시스템과 비교한 복합식 제습냉방시스템의 냉각 열량증가에 관한 실험적 연구
Study on the Energy Efficiency Improvement of Hybrid Dehumidification Air Conditioning System Compared with Refrigeration System

이수동   (한국기술교육대학교 대학원UU0001384  ); 박문수   (한국생산기술연구원 청정설계기술팀CC0186930  ); 정진은   (한국기술교육대학교 기계공학부UU0001384  ); 최영석   (한국생산기술연구원 청정설계기술팀CC0186930  );
  • 초록

    The hybrid liquid desiccant air conditioning system has been in use for many years, primarily in industrial process applications requiring dehumidification and humidity control. In this study, the hybrid dehumidifier has been designed to study the dehumidification characteristic of the aqueous triethylene glycol (TEG) solution. The experimental results show energy efficient characteristics of hybrid liquid desiccant air conditioning system compared with the refrigeration system in terms of energy use, the difference of pressure loss between hybrid liquid desiccant air conditioning system and refrigeration system. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.


  • 주제어

    액체 건조제 .   제습 .   제습기 .   냉각 .   흡수 .   트리에틸렌글리콜.  

  • 참고문헌 (8)

    1. Park, M. S., 1998, R&D Trend in desiccant based dehumidication and hybrid cooling sys-tem, SAREK Paper, Vol. 27, No.6, pp.533-540 
    2. Seo, J. H., 1989, An absorption dehumidifi-cation System, KARSE Paper, Vol. 6, No.6, pp.54-58 
    3. Lee, S. D., Park. M. S., Chung, J. E. and Choi, Y. S., 2003, Study on the performance char-acteristics with the height of a regenerator and dehumidifier for liquid desiccant dehu-midification system, KSME Paper, Vol. 28, No.5, pp. 593-602 
    4. lee, K. H., Park, M. S., Kang, K. T. and Lee, J. S., 2001, Experimental study on perfor-mance of the fin-tube type liquid desiccant Dehumidifier, Proceedings of the SAREK 2001 Winter Annual Conference, pp.206-211 
    5. Jang, J. O., 2003, Study on the effect of performance factors on the finned tube type regenerator for liquid desiccant dehumidifi-cation, KSME Paper, Vol. 27, No.7, pp.845-852     
    6. Union Carbide Corp, 1989, Triethylene Gly-col, New York 
    7. Lee, S. D., Park, M. S., Chung, J. E. and Lee, J. S., 2003, An experimental study on the performance characteristic with height of a fin-tube liquid desiccant dehumidifier, Pro-ceedings of the KSME 2003 Winter Annual Conference, pp.25-30 
    8. Mechler, P. E., 1986, Solar cooling system reduces summer utility demand and HVAC system life cycle in commercial and insti-tutional buildings, Intersociety Energy Con-vert, San Diego, Proc. 21st 
  • 이 논문을 인용한 문헌 (4)

    1. Choi, Yong-Don ; Kang, Yong-Tae ; Kim, Nae-Hyun ; Kim, Man-Hoe ; Park, Kyoung-Kuhn ; Park, Byung-Yoon ; Park, Jin-Chul ; Hong, Hi-Ki 2007. "Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 -" 설비공학논문집 = Korean journal of air-conditioning and refrigeration engineering, 19(1): 94~131     
    2. Ku, Hak-Keun 2010. "A Study on Performance Characteristics of a Dehumidifier with Multi-layer Type Heat Exchangers Varying Frontal Air Velocity" 한국산학기술학회논문지 = Journal of the Korea Academia-Industrial cooperation Society, 11(7): 2323~2327     
    3. Choi, Younhee ; Song, Doosam ; Sohn, Won-Woo ; Lim, Younghoon 2015. "Analysis of Indoor Temperature and Humidity Changes with the Operation of the Condense Drying Dehumidifier" 설비공학논문집 = Korean journal of air-conditioning and refrigeration engineering, 27(12): 626~632     
    4. Kim, Jong-Ryeol 2016. "Development of High Efficiency Dehumidifiers in low temperature" 한국산학기술학회논문지 = Journal of the Korea Academia-Industrial cooperation Society, 17(9): 206~211     

 저자의 다른 논문

  • 이수동 (4)

    1. 2004 "액체식 제습시스템을 위한 재생기와 제습기의 높이에 따른 성능특성에 관한 연구" 설비공학논문집 = Korean journal of air-conditioning and refrigeration engineering 16 (7): 630~638    
    2. 2004 "휜-튜브형 액체건조제 제습기의 높이에 따른 성능특성에 관한 실험적 연구" 大韓機械學會論文集. Transactions of the Korean Society of Mechanical Engineers. B. B 28 (5): 594~603    
    3. 2004 "연료전지 분리판 압력손실 감소를 위한 수치해석 및 실험적 연구" 한국수소 및 신에너지학회 논문집 = Transactions of the Korean Hydrogen and New Energy Society 15 (2): 159~165    
  • 박문수 (12)

  • 정진은 (9)

  • 최영석 (36)

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • NDSL :
유료다운로드

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 이용한 콘텐츠
이 논문과 함께 출판된 논문 + 더보기