RESONANCE FREQUENCY ANALYSIS OF IMPLANTS WITH ANODIZED SURFACE OXIDES

Choi Jeong-Won    (Department of Prosthodontics, Graduate School, Seoul National University   ); Heo Seong-Joo    (Department of Prosthodontics, Graduate School, Seoul National University   ); Chang Ik-Tae    (Department of Prosthodontics, Graduate School, Seoul National University   ); Koak Jai-Young    (Department of Prosthodontics, Graduate School, Seoul National University   ); Han Jong-Hyun    (Yonsei University, Yongdong Severance Hospital   ); Kim Yong-Sik    (University of Ulsan, Asan Medical Center   ); Lee Seok-Hyung    (Department of Prosthodontics, Samsung Medical Center, College of Medicine, Sungkyunkwan University   ); Yim Soon-Ho    (Department of Prosthodontics, Samsung Medical Center, College of Medicine, Sungkyunkwan University  );
  • 초록

    The present experimental study was designed to address two issues. The first was to investigate whether oxidation voltage of titanium implants influenced bone tissue responses after an in vivo implantation. The second aim was to investigate secondary stability change after 1 to 3months period. Screw-shaped implants with a wide range of oxide properties were prepared by electrochemical oxidation methods, where the oxide thickness varied in the range of $3-15{\mu}m$ . The micro structure revealed pore sizes of $1-3{\mu}m$ , the crystal structures of the titanium oxide were amorphous, anatase and a mixture of anatase and rutile type. Bone tissue responses were evaluated by resonance frequency measurements that were undertaken 1 to 3months after insertion in the rabbit tibia. It was concluded that no statistical difference of RFA values was found between the groups, RFA gains after Imonth and 3months were calculated.


  • 주제어

    Anodic oxidation .   Resonance frequency analysis .   Titanium implant .   Voltage.  

  • 참고문헌 (10)

    1. Albrektsson, T., Branemark, P.I., Hansson, H.A. & Lindstrom, J. Osseointegrated titanium implants. Acta Orthopaedica Scandinavica 1981;52:155-179 
    2. Sul, Y.T., Johansson, C.B., Petronis, S., Krozer, A., Jeong, Y., Wennerberg, A & Albrektsson, T. Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: The oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition. Biomaterials 2002;23: 491-501 
    3. Larsson, C, Thomsen, P., Aronsson, B.O., Lausmaa, J., Rodahl, M. & Kasemo, B. Bone response to surface-modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thickness. Biomaterials 1996;15:605-616 
    4. van Steenberghe, D., ed. Proceedings of the International Congress on Tissue Integration inOral and Maxillo-Facial Reconstruction. New York: ExcerptMedica 1986 
    5. Esposito, M., Lausmaa, J., Hirsch, J.M. & Thomsen, P. Surface analysis of failed oral titanium im-plants. Journal of Biomedical Materials Research 1999;48: 559-568 
    6. Meredith, N., Shagaldi, F., Alleyne, D., Sennerby, L. & Cawley, P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clinical Oral Implants Research 1997;8:234-243 
    7. Sennerby, L., Thomsen, P. & Ericson, L.E. Ultrastructure of the bone-titanium interface in rabbits. Journal of Materials Science: Materials in Medicine 1992;3:262-271 
    8. Oron, U. & Hazan, R. Method of treating a metal prosthetic device prior to surgical implantation to enhance bone growth relative thereto following implantation. US Patent Number 5 080 671, 1992 
    9. Albrektsson, T., Branemark, P.I., Hansson, H.A., Kasemo, B., Larsson, K., Lindstrom, I., McQueen, D. & Skalak, R. The interface zone of inorganic implants in vivo: titaniumimplants in bone. Annals of Biomedical Engineering 1983;11: 1-27 
    10. McQueen, D., Sundgren, J.E., Ivarsson, B., Lindstrom, I., Ekenstam, B.F., Svensson, A., Albrektsson, T. & Branemark, P.I. Auger electron spectroscopic studies of titanium implants. In: Lee, A.J.C., Albrektsson, T. & Branemark, P.I., eds. Clinical Applications of Biomaterials, 1982;179-185. New York: John Wiley & Sons 

 저자의 다른 논문

  • Heo, Seong-Joo (78)

    1. 1994 "두개하악장애 환자의 하악운동에 관한 연구" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 32 (1): 103~119    
    2. 1996 "저작형태가 교합면 마모에 미치는 영향에 관한 연구" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 34 (1): 15~30    
    3. 1996 "상악 구개부 결손의 보철치료에 관한 임상적 연구" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 34 (1): 201~210    
    4. 1996 "측두하악관절장애 환자의 보철치료" 大韓齒科醫師協會誌 = The journal of the Korean dental association 34 (4): 271~275    
    5. 1997 "편측저작시 하악골 과두의 응력분포에 관한 삼차원 유한요소분석적 연군" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 35 (3): 517~534    
    6. 1997 "임플란트 생체금속들과 골조직간의 생체적합도에 관한 연구" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 35 (3): 557~565    
    7. 1997 "골유착성 임플랜트 고정체의 설계변화에 따른 응력분포에 관한 삼차원 유한요소 분석적 연구" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 35 (3): 609~621    
    8. 1998 "식품의 물성이 제작근의 활성도 및 저작 양태에 미치는 영향" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 36 (3): 427~452    
    9. 1998 "중심위 교합-최대교두감합위 불일치가 치아 마모에 미치는 영향에 관한 연구" 대한치과보철학회지 = The journal of Korean academy of prosthodontics 36 (5): 683~700    
    10. 1998 "타이태늄 합금의 생체적합도에 관한 연구" 대한치주과학회지 = The journal of Korean academy of periodontology 28 (3): 401~408    
  • 장익태 (84)

  • Han Jong-Hyun (1)

  • Kim Yong-Sik (1)

  • 임순호 (13)

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기