Experimental analysis of a semi-actively controlled steel building

Occhiuzzi, Antonio    (Department of Structural Analysis and Design, School of Engineering, University of Napoli Federico II   ); Spizzuoco, Mariacristina    (Department of Structural Analysis and Design, School of Engineering, University of Napoli Federico II  );
  • 초록

    The strong need of verifying theories formulated for semi-active control through applications to real structures is due to the fact that theoretical research on semi-active control systems is not matched by a corresponding satisfactory experimental activity. This paper shows how a smart system including magnetorheological devices as damping elements can be implemented in a large-scale structural model, by describing in detail the kind of electronics (dedicated hardware and software) adopted during the experimental campaign. It also describes the most interesting results in terms of reduction of the seismic response (either experimental or numerical) of the semi-actively controlled structure compared to a passive operating control system, and in terms of the evaluation criteria proposed in the benchmark for seismically excited controlled buildings. The paper also explains how to derive from the classical theory of optimal control the adopted control logic, based on a clear physical approach, and provides an exhaustive picture of the time delays characterizing the control sequence.


  • 주제어

    semi-active control .   magnetorheological dampers .   large scale tests.  

  • 참고문헌 (26)

    1. Yang, N.J. and Akbarpour, A. (1987), 'New optimal control algorithms for structural control', J. Eng. Mech., 113, 1369-1386 
    2. Chen, Z.Q., Wang, X.Y., Ko, J.M., Ni, Y.Q., Spencer, B.F., Yang, G. and Hu, J.H. (2004), 'MR damping system for mitigating wind-rain induced vibration on Dongting Lake Cable-Stayed Bridge', Wind and Structures, 7(5), 293-304 
    3. Chu, S.Y., Soong, T.T., Reinhorn, A.M., Helgeson, R.J. and Riley, M.A. (2002), 'Integration issues in implementation of structural control systems', J. Struct. Control, 9, 31-58 
    4. De Luca, A. and Serino, G. (1988), 'Lapproccio energetico nella progettazione sismica', Ingegneria Sismica, Anno, V(3), 18-27 (in Italian) 
    5. Hiwatashi, T., Shiozaki, Y., Fujitani, H., Iiba, M., Tomura, T., Sodeyarna, H. and Soda, S. (2002), 'Semi-active control of large-scale test frame by magneto-rheological damper', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 2, 355-360 
    6. Inaudi, J.A. and Hayen, J.C (1995), 'Research on variable-structure systems in the United States', Proc. Post-SMiRT Conf. Sem. on Seismic Isolation, Passive Energy Dissipation and Control of Vibrations, Santiago, Cile: GLIS, 591-622 
    7. Inaudi, J.A. (2000), 'Performance of variable-damping systems: Theoretical analysis and simulation', Proc. 3rd Int. Workshop on Structural Control, ed F Casciati & Magonette, United Kingdom: World Scientific, 301-316 
    8. Jung, H.J., Spencer, B.F., Ni, Y.Q. and Lee, I.W. (2004), 'State-of-the-art of semiactive control systems using MR fluid dampers in civil engineering applications', Struct. Eng. Mech., 17(3), 493-526   
    9. Kobori, T. (2002), 'Past, present and future in seismic response control of civil engineering structures', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 1, 9-14 
    10. Luenberger, D.G. (1979), Introduction to Dynamic Systems - Theory, Models & Applications, John Wiley & Sons Inc., USA 
    11. Medeot, R., Braun, C., Seiler, C., Debost, S., Hedin, F., Bergamo, G., Forni, M., Bettinali, F., Serino, G. and Fuller, K.N.G. (2001), 'The EC-funded project SPACE (Semi-Active and Passive Control of the Dynamic Behavior of Structures Subjected to Earthquakes, Wind and Vibrations)', Proc. 7th Int. Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control of Vibrations of Structures, Assisi, Italy: GLIS, 1, 447-475 
    12. Morishian, S., Shiraishi, T. and Nakaya, N. (2002), 'Adaptive vibration control of a structure using MR damper', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 3, 761-766 
    13. National Instruments (2000), LabVIEW$^{TM}$ - User Manual, National Instruments Corp., Austin, Texas - USA 
    14. Nishitani, A. and Inoue, Y. (2001), 'Overview of the application of active/semiactive control to building structures in Japan', Earth. Eng. Struct. Dyn., 30, 1565-1574 
    15. Occhiuzzi, A. and Serino, G. (2002), 'Control strategies for semi-active structural control devices', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 3, 641-647 
    16. Occhiuzzi, A. and Spizzuoco, M. (2003), 'Semi-active magnetorheological dampers applied to a steel building', Proc. Forth Int. Conf. on Behaviour ofSteel Structures in Seismic Areas, ed F M Mazzolani, The Netherlands: Balkema, 633-639 
    17. Occhiuzzi, A., Spizzuoco, M. and Serino, G. (2003), 'Experimental analysis of magnetorheological dampers for structural control', Smart Mater. Struct., 12, 703-711 
    18. Serino, G., Occhiuzzi, A., Spizzuoco, M., Seiler, C. and Fischer, O. (2002), 'Semi-active control via MR dampers: Algorithms, numerical modeling and prediction of the resulting response of structures', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 2, 1113-1118 
    19. Spencer, B.F. and Nagarajaiah, S. (2003), 'State of the art of structural control', J. Struct. Engrg., 129, 845-856 
    20. Symans, M.D. and Constantinou, M.C. (1999), 'Semi-active control systems for seismic protection of structures: A state-of-the-art review', Eng. Struct., 21, 469-487 
    21. Tagami, J., Koshida, H., Kurino, H., Sugiyama, T., Suwa, M. and Mori, F. (2002), 'Forced vibration test of an 11-storey building with semi-active switching oil damper', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 2, 75-80 
    22. University of Illinois Urbana-Champaign - Department of Civil and Environmental Engineering http://cee.uiuc.edu/sstl/benchmarks 
    23. Wongprasert, N. and Symans, M.D. (2002), 'Experimental evaluation of a smart base-isolation system consisting of spherical sliding bearings and variable fluid dampers', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 2, 331-336 
    24. Yamamoto, M., Higashino, M. and Aizawa, S. (2002), 'Development of semi-active mass damper system using oil damper with solenoid valves', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 2, 343-348 
    25. Yang, G., Spencer, B.F., Carlson, J.D. and Sain, M.K. (2002), 'Large-scale MR fluid dampers: Modeling and dynamic performance considerations', Eng. Struct., 24, 309-323 
    26. Yang, N.J., Li, Z. and Liu, S.C. (1992), 'Stable controllers for istantaneous optimal control', J. Eng. Mech., 118, 1612-1630 
  • 이 논문을 인용한 문헌 (1)

    1. 2015. "" Smart structures and systems, 15(4): 963~995     

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.
유료다운로드

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기