확산길이에 따른 수동식 유기용제 시료채취기의 시료채취성능에 관한 연구
Sampling Efficiency of Organic Vapor Passive Samplers by Diffusive Length

이병규   (한국산업안전보건공단 부산지역본부  ); 장재길   (한국산업안전보건공단 산업안전보건교육원  ); 정지연   (용인대학교 환경보건학과  );
  • 초록

    Passive samplers have been used for many years for the sampling of organic vapors in work environment atmospheres. Currently, all passive samplers used in domestic occupational monitoring are foreign products. This study was performed to evaluate variable parameters for the development of passive organic samplers, which include the geometry of the device and diffusive length for the sampler design. Four prototype diffusive lengths; A-1(4.5 mm), A-2(7.0 mm), A-3(9.5 mm), A-4(12.0 mm) were tested for adsorption performances to a chemical mixture (benzene, toluene, trichloroethylene, and n-hexane) according to the US-OSHA's evaluation protocol. A dynamic vapor exposure chamber developed and verified by related research was used for this study. The results of study are as follows. The results in terms of sampling rate and recommended sampling time test indicate that the most suitable model was A-3 (9.5 mm diffusive lengths on both sides) for passive sampler design in time weighted average (TWA) assessment. Sampling rates of this A-3 model were 45.8, 41.5, 41.4, and 40.3 ml/min for benzene, toluene, trichloroethylene, and n-hexane, respectively. The A-3 models were tested on reverse diffusion and conditions of low humidity air (35% RH) and low concentrations (0.2 times of TLV). These conditions had no affect on the diffusion capacity of samplers. In conclusion, the most suitable design parameters of passive sampler are: 1) Geometry and structure - 25 mm diameter and 490 $mm^2$ cross sectional area of diffusion face with cylindrical form of two-sided opposite diffusion direction; 2) Diffusive length - 9.5 mm in both faces; 3) Amount of adsorbent - 300 mg of coconut shell charcoal; 4) Wind screen - using nylon net filters (11 ${\mu}m$ pore size).


  • 주제어

    passive sampler .   sampling rate .   diffusive length .   evaluation protocol.  

  • 참고문헌 (28)

    1. United Kingdom Health and Safety Executive (HSE) : Volatile organic compounds in air in methods for the determination of hazardous substances. 1997 
    2. Pristas, R. : Passive badges for compliance monitoring internationally. American Industrial Hygiene Association Journal, 55(9), 841-844, 1994 
    3. Byeon, S. H., Park, C. J., Oh, S. M., Lee, C. H. : The sampling efficiencies of volatile organic compounds (VOCs) to the diffusive monitor with activated carbon fiber. Korean Industrial Hygiene Association Journal, 6(2), 187-201, 1996 
    4. Cho, S. J., Paik, N. W. : Field comparison of korean diffusive sampler and charcoal tube methods for determination of organic vapors. Korean Industrial Hygiene Association Journal, 7(1), 33-48, 1997 
    5. Ministry of Labor (MOL) : Occupational Safety and Health Law. Threshold limit Values for chemical Substances and Physical Agents exposure indices. Notice No. 2007-25, 2007 
    6. Yi, G . Y., Park, D. Y ., Jeon g, J . Y. : E ffects of t he pore size of t he p assive s ampler's w in dscreen to the sampling rates. Journal of Korean Society of Occupational and Environmental Hygiene, 14(2), 125-133, 2004 
    7. National Institute of Occupational Safety and Health (NIOSH) : Hydrocarbons, Aromatic (Method 1501) in NIOSH Manual of Analytical Method (NMAM). 1994 
    8. Gregory, E. D., Elia, V. J. : Sample retention properties of passive organic vapor samplers and charcoal tubes under various conditions of sample loading, relative humidity, zero exposure level periods and a competitive solvent. American Industrial Hygiene Association Journal, 44(2), 88-96, 1983 
    9. Byeon, S. H., Thomas, H. S., Maria, T. M., Afshar, M., Jay, C. : The effects of face velocity and path length on the uptake rates of volatile organic compounds measured by diffusive samplers. Journal of Korean Society of Occupational and Environmental Hygiene, 11(1), 34-41, 2001 
    10. Lee, B. K., Jeong, J. Y., Yi, G. Y., Kim, B. Y. : Development of standard vapor generation system. 2006 Winter conference of Korean society of occupational and environmental hygiene. Korean Society of Occupational and Environmental Hygiene, 102-104, 2006 
    11. Paik, N. W., Kong, S. H., Park, J. I., Lee, Y. H. : Evaluation of commercially available passive samplers and development of new passive samplers. Part 2: Development of new passive samplers. Korean Industrial Hygiene Association Journal, 6(1), 97-108, 1996 
    12. International Organization for Standardization (ISO) : Workplace atmospheres-Protocol for evaluating the performance of diffusive samplers. ISO/TC146/SC2 DIS 16107, 2006 
    13. Paik, N. W., Park, D. W., Yoon, C. S. : Measurement and evaluation for occupational environment. Singwang press, 1999 
    14. Occupational Safety and Health Administration (OSHA). Evaluation guidelines for air sampling methods utilizing chromatographic analysis. Available from:URL:http://www.osha.gov/dts/sltc/methods/chromguide/chromguide.html. 1999 
    15. Yim, B., Kim, S. T. : Evaluation of an ammonia passive sampler using chamber system. Journal of Korean Society for Atmospheric Environment, 22(E1), 1-8, 2006     
    16. Han, J. G., Roh, Y. M., Kim, H. W. : Effects of temperature and relative humidity on the sampling efficiencies of mixed organic vapors measured by diffusion monitors. Korean Industrial Hygiene Association Journal, 5(2), 200-211, 1995 
    17. Cassinelli, M. E., Hull, R. D., Crable, J. V., Teass, A. W. : Protocol for the evaluation of passive monitors. In diffusive s ampling: An alternative approach to workplace air monitoring, A. Berlin, R.H. Brown, and K.J. Saunders (Royal Society of Chemistry, London)(eds.), NIOSH Protocol for the evaluation of passive monitors, 190-202, 1987 
    18. Ministry of Labor (MOL) : Usability of passive sampler for working environment measurement in question and an swer i n in dustrial health a nd safety law. 2001 
    19. Paik, N. W., Yoon, C. S. : Field evaluation korean passive sampler for organic vapor. Korean Industrial Hygiene Association Journal, 8(1), 124-132, 1998 
    20. Palmes, E. D., Burton Jr, R. M., Ravishankar, K., Solomon, J. J. : A simple mathematical model for diffusional sampler operation. American Industrial Hygiene Association Journal, 47(7), 418-420, 1986 
    21. Kim, S. T., Yim, B., Jung, J. : Development of a passive a ir sampler for the measurement of indoor formaldehyde. Analytical Science, 23(4), 497-500, 2007 
    22. Paik, N. W., Park, M. J., Yoon, C. S. : Evaluation of commercially available passive samplers and development of n ew passive s amplers. P art 1: Evaluation of commercially avaliable passive samplers. Korean Industrial Hygiene Association Journal, 6(1), 109-124, 1996 
    23. Park, M. J., Yoon, C. S., Paik, N. W. : A study on organic solvent measurement using diffusive sampler. Korean Industrial Hygiene Association Journal, 4(2), 208-223, 1994 
    24. National Institute of Occupational Safety and Health (NIOSH) : Toluene (diffusive sampler) (Method 4000) in NIOSH Manual of Analytical Method (NMAM). 1994 
    25. Yim, B ., J un g, E . : Badge-type d iffusive s ampler using 3-Methyl-2-benzothiazolinone hydrazone for measuring formaldehyde in indoor air. Analytical Science, 22(7), 993-997, 2006 
    26. Kim, S. K., Yim, B., Jung, E. S., Kim, S. T. : Development and evaluation of a badge-type passive sampler for the measurement of short-term nitrogen dioxide in ambient air. Journal of Korean Society for Atmospheric Environment, 22(1), 117-126, 2006     
    27. United Kingdom Health and Safety Executive (HSE) : Protocol for assessing the performance of a diffusive sampler in methods for the determination of hazardous substances. 1994 
    28. Comite Europeen de Normalisation (CEN) : Workplace atmospheres-diffusive samplers for the determination of gases and vapours-Requirements and test methods. (EN 838) Comite Europeen de Normalisation, Brussels, Belgium, 1995 

 저자의 다른 논문

  • 이병규 (11)

    1. 2002 "공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도-" 한국대기환경학회지 = Journal of Korean Society for Atmospheric Environment 18 (1): 39~49    
    2. 2002 "현장 도금 공정에서 PVC 여과지에 채취된 6가 크롬의 환원" 한국환경위생학회지 = Korean journal of Environmental Health Society 28 (1): 41~49    
    3. 2003 "도금공정 공기중 6가 크롬 시료채취여과지 비교에 관한 연구" 한국환경위생학회지 = Korean journal of Environmental Health Society 29 (2): 69~76    
    4. 2005 "석유계 솔벤트를 사용하는 세탁소 작업자의 노출평가" 한국산업위생학회지 = Journal of Korean Society of Occupational and environmental hygiene 15 (1): 19~26    
    5. 2008 "업무용 빌딩 소재 사무실의 실내환기 평가" 한국산업위생학회지 = Journal of Korean Society of Occupational and environmental hygiene 18 (2): 115~121    
    6. 2010 "국내 정부출연연구기관 및 대학교 실험실 공기 오염물질 농도 및 환기시스템 평가" 한국산업위생학회지 = Journal of Korean Society of Occupational and environmental hygiene 20 (1): 63~69    
    7. 2010 "석유 및 석탄화학의 대보수작업중 벤젠노출 특성 비교" 한국산업위생학회지 = Journal of Korean Society of Occupational and environmental hygiene 20 (3): 147~155    
  • 장재길 (16)

  • 정지연 (13)

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
유료다운로드

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 이용한 콘텐츠
이 논문과 함께 출판된 논문 + 더보기