Pseudomeningitis again. Association with cytocentrifuge funnel and Gram-stain reagent contamination.

Southern, P M Colvin, D D
  • 초록  

    OBJECTIVE--To report an "epidemic" of pseudomeningitis related to cytocentrifuge funnel and Gram-stain reagent contamination, and our evaluation and responses. DESIGN--Investigation was stimulated by the recognition of Gram-stained, smear-positive, culture-negative cerebrospinal fluid (CSF) specimens. Cytofunnels, glass slides, Gram-staining reagents, and an automated Gram-staining apparatus were subjected to repeated staining and culture. Control stains and cultures using fetal bovine serum (simulated CSF) were performed for comparison. SETTING--The clinical microbiology laboratory of Parkland Memorial Hospital, a large acute-care teaching hospital. SPECIMENS--Cerebrospinal fluid specimens were submitted to the clinical microbiology laboratory in the course of routine patient care. MAIN OUTCOME MEASURES--Gram's stains and cultures of test and control preparations. RESULTS--Most of the smear-positive, culture-negative, original CSF specimens contained Gram-positive bacilli or Gram-negative bacilli. Smears of cytofunnels revealed similar organisms, and cultures revealed Bacillus species. Cytofunnels from several lots were culture-positive. Glass slides were not contaminated. Of 25 CSF specimens stained during the initial week of investigation, 23 were negative by culture and two grew Cryptococcus neoformans (from acquired immunodeficiency syndrome patients). Control stains and cultures of simulated CSF were negative. Gram-stain reagents were frequently smear-positive, and cultures repeatedly yielded Flavimonas oryzihabitans from the crystal violet well of an automated Gram-staining apparatus. These latter contaminants could not be eliminated consistently. INTERVENTIONS--No alternative sources of cytofunnels were found. The Gram-staining apparatus was cleaned and reagents changed frequently. Cytocentrifugation and use of automated Gram staining was discontinued for CSF and other normally sterile fluids. The laboratory staff was repeatedly educated about the problem. CONCLUSIONS--Contamination of cytocentrifuge funnels and an automated Gram-staining apparatus contributed to an "epidemic" of pseudomeningitis. The problem was corrected by education of the laboratory staff and by altered management of CSF and other sterile body fluid specimens.


 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.
유료다운로드
  • ProQuest Science Journals : 저널
  • ProQuest Nursing and Allied Health Source : 저널
  • ProQuest Medical Library : 저널
  • ProQuest Central : 저널

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기