Yun, Mi-Ja    (Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.   ); Na, Hyo-Seok    (Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.   ); Shin, Young Duck    (Department of Anesthesiology and Pain Medicine, Chungbuk National University College of Medicine, Cheongju, Korea.   ); Han, Jun-Sung    (Department of Anesthesiology and Pain Medicine, Chungbuk National University College of Medicine, Cheongju, Korea.   ); Hwang, Jung-Won    (Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.   ); Kim, Chong Soo    (Department of Anesthesiology and Pain Medicine, Seoul National University Boramae Hospital, Seoul, Korea.   ); Bae, Jin Ho    (Department of Anesthesiology and Pain Medicine, Chungbuk National University College of Medicine, Cheongju, Korea.  );
  • 초록

    Background We introduce a new, simple portable inhalational induction device (PD) that provides co-operative inhalational induction of anaesthesia using N 2 O and subsequent sevoflurane in the preanaesthetic induction area in children. Methods Forty-five children (30 to 94 months old age, 2 O followed by sevoflurane (PD N 2 O-sevo group) or sevoflurane (PD sevo group) using a portable inhalational induction device in the preanaesthetic induction area until they were unable to respond to their names. They were then transferred to the operating room while maintaining inhalation of sevoflurane via the device. The control group underwent conventional inhalational induction in the operating room with the parents in attendance. Results Patients in the PD N 2 O-sevo group had a higher co-operative inhalation frequency than the patients in the PD sevo or the control group. Anaesthesia induction in the PD N 2 O-sevo and the PD sevo groups were faster than in the control group. Parent satisfaction score (0-100) was higher for the PD N 2 O-sevo group than for the control group. Conclusions A new portable inhalational induction device allows faster induction in co-operation with parents present in the preanaesthetic induction area compared to conventional inhalational induction in the unfamiliar operating room with the parents in attendance.


  • 주제어

    Inhalation induction .   Nitrous oxide .   Potable instrumentation .   Sevoflurane.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

유료다운로드

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기