European heart journal cardiovascular Imaging v.18 no.2, 2017년, pp.159 - 166   SCIE
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

Optical coherence tomography evaluation of intermediate-term healing of different stent types: systemic review and meta-analysis

Iannaccone, Mario (Division of Cardiology, Cittèà ) ; D'Ascenzo, Fabrizio (Della Salute e Della Scienza, Turin, Italy ) ; Templin, Christian (Division of Cardiology, Cittèà ) ; Omedè, Pierluigi (Della Salute e Della Scienza, Turin, Italy ) ; Montefusco, Antonio (University Heart Center, Cardiology, University Hospital, Zurich, Switzerland ) ; Guagliumi, Giulio (Division of Cardiology, Cittèà ) ; Serruys, Patrick W. (Della Salute e Della Scienza, Turin, Italy ) ; Di Mario, Carlo (Division of Cardiology, Cittèà ) ; Kochman, Janusz (Della Salute e Della Scienza, Turin, Italy ) ; Quadri, Giorgio (Cardiovascular Department, Ospedali Riuniti di Bergamo, Bergamo, Italy ) ; Biondi-Zoccai, Giuseppe (Department of Interventional Cardiology, Erasmus University Medical Centre, Thoraxcenter, Rotterdam, The Netherlands ) ; Luscher, Thomas F. (National Institute of Health Research Cardiovascular Biomedical Research Unit, Royal Brompton & Harefield NHS Foundation Trust, London, UK ) ; Moretti, Claudio (Department of Cardiology, Warsaw Medical University, Warszawa, Poland ) ; D'amico, Maurizio (Division of Cardiology, Cittèà ) ; Gaita, Fiorenzo (Della Salute e Della Scienza, Turin, Italy ) ; Stone, Gregg W. (Department of Medico-Surgical Sciences and Biotechnologies, Sapie ) ;
  • 초록  

    Aims The intermediate-term incidence of strut malapposition (SM) and uncovered struts (US), and the degree of neointimal thickness (NIT) according to stent type have not been characterized. Methods and results All studies of >50 patients in which optical coherence tomography was performed between 6 and 12 months after stent implantation were included. The incidences of SM and US were the co-primary end points, while NIT was the secondary end point. A total of 458 citations were initially appraised at the abstract level, and 11 full-text studies (280 652 analysed struts, 921 patients) were assessed. The 6–12 months incidences of SM and US were 5.0 and 7.8%, respectively, and the mean NIT was 206 μm. Biolimus-eluting stents (BES) and bioresorbable vascular scaffolds (BVS) had the highest SM rates (2.7 and 3.8%, respectively), while everolimus-eluting stents (EES) and fast-release zotarolimus-eluting stents (ZES) had the lowest SM rates (0.9 and 0.1%, respectively). BES and sirolimus-eluting stents (SES) had the highest US rates (7.7 and 8.8%, respectively), while bare metal stents (BMS) and ZES had the lowest US rates (0.3 and 0.3%, respectively). BMS had the greatest NIT (340 μm), while SES, EES, and BES had the least NIT. Conclusion Second-generation drug-eluting stents (DES) have better intermediate-term strut apposition and coverage than first-generation DES, BVS, and BMS. EES demonstrate the overall best combination of healing with suppression of neointimal hyperplasia at 6–12 months. Further studies with clinical correlation are warranted to determine the implications of these findings.


  • 주제어

    optical coherence tomograph .   OCT .   drug-eluting stent .   BV .   EES .   strut malapposition .   strut uncoverage .   neointima thickness.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기