Structural performance of FCS wall subjected to axial load

Mohamad, Noridah (Faculty of Civil and Environmental Engineering, Universiti Tun Hussein Onn Malaysia, Malaysia ); Goh, Wan Inn (Faculty of Civil and Environmental Engineering, Universiti Tun Hussein Onn Malaysia, Malaysia ); Abdullah, Redzuan (Faculty of Civil Engineering, Universiti Teknologi Malaysia, Malaysia ); Samad, Abdul Aziz Abdul (Faculty of Civil and Environmental Engineering, Universiti Tun Hussein Onn Malaysia, Malaysia ); Mendis, Priyan (Department of Infrastructure Engineering, The University of Melbourne, Australia ); Sofi, Massoud (Department of Infrastructure Engineering, The University of Melbourne, Australia );
  • 초록  

    Abstract The primary purpose of this paper is to present the structural behavior of precast foamed concrete sandwich walls (FCS) strengthened with double steel shear connectors (DSC) subjected to axial load. The discussion of results addresses the effect of slenderness ratio (H/t) on the behavior of the walls. It also addresses the significant effects of using double shear connectors on these behaviors compared to single steel shear connector (SSC). The FCS wall was modeled using ABAQUS and validated by the results from experiment and previous research. Parametric finite element study (FEA) was conducted by simulating these walls with various H/t under axial load. The structural behavior recorded from FEA includes its ultimate load, failure mode, load-deflection profiles, strain distribution across the wall’s thickness, and ultimate shear load. It was found that as H/t increased, the ultimate load decreased but the maximum horizontal deflection increased. FCS with H/t ⩽25 failed from crushes and cracks within the top and bottom area while FCS with H/t ⩾25 failed from buckling at its mid-height. It was also noticed that FCS with lower H/t experienced more uniform strain distribution across its thickness. FCS with DSC was able to sustain higher load but it deflected less compared to walls with SSC, caused by higher stiffness due to larger steel areas. It is interesting to find that FCS walls with DSC behaved in a more composite manner and was able to sustain higher ultimate shear force under push of loading test compared to FCS walls with SSC. These findings show that the FCS wall with DSC is suitable to be used as a load-bearing wall. Highlights The ultimate load, load-deflection profile and strain distribution of FCS wall subjected to axial load are obtained. The effects of various slenderness ratio of FCS walls strengthened with DSC on its structural behavior are obtained. The ultimate shear load of FCS walls under push off load test is obtained. FCS walls with DSC attained higher ultimate load and composite action compared to walls with SSC. FCS wall strengthened with DSC is found to behave in a partially composite manner.


  • 주제어

    Foamed concrete sandwich wall .   Double shear connector .   Slenderness ratio .   Structural behavior.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기