Radiographic modelling for NDE of subsea pipelines

Haith, M.I. Ewert, U. Hohendorf, S. Bellon, C. Deresch, A. Huthwaite, P. Lowe, M.J.S. Zscherpel, U.
  • 초록  

    This work presents an investigation of the accuracy of a radiographic simulation model applied to subsea pipeline inspections. Experimental measurements of a sample in a water tank are used to develop a set of calibrated simulation parameters for the modelling software aRTist. Image quality parameters such as signal-to-noise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. With this method signal-to-noise ratio was successfully matched while differences were still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough, however wall thickness measurements in tangential images, which are not based on absolute intensity, were found to produce similar results in simulated and experimental cases. The differences in contrast and intensity are thought to be due to detector backscatter and additional scatter from out-of-setup objects within the exposure bay, due to a lack of source collimation. These would affect the experimental results but were not included in the simulated setup. This was investigated by including different proportions of peripheral water and other objects in the modelled setup and examining the effect on image quality parameters. Results show that this additional scatter has a significant impact on the radiograph, particularly on image contrast, and is therefore the likely cause of differences between experimental and simulated images. This implies that it will be very difficult to completely match simulated to experimental results, as including all possible scattering objects in the model would be very complex. An improvement could be made by using real subsea data to estimate this additional scattering, which could then be used to calibrate the model. However there would still be significant uncertainty in the ability of the model to accurately produce realistic intensity and contrast.


  • 주제어

    Digital radiography .   Modelling validation .   Subsea pipeline inspection .   Tangential radiography.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기