Evaluation of new low-cost particle monitors for PM2.5 concentrations measurements

Zikova, N. Hopke, P.K. Ferro, A.R.
  • 초록  

    Sixty-six, new, low-cost Speck monitors were collocated with a Grimm 1.109 particle spectrometer and CO loggers during one indoor and two outdoor monitoring campaigns to assess the ability of the monitors to measure the PM concentrations under real use conditions. The limit of detection of the monitors was calculated, and the monitors' bias and precision, as well as the results' reproducibility, were determined. Correlation coefficients of 0.3 and 0.2 observed between the Speck units and the Grimm instrument during indoor and outdoor measurements were increased by separating the data into sets affected by different sources. When the ambient data were divided into combustion and non-combustion aerosol, the mean r 2 increased to 0.5 and 0.4 for indoor and outdoor combustion periods data, respectively. Also, averaging the data to improve the signal to noise ratio increases the correlation for low PM concentrations. For outdoor data, the correlation increased to 0.5 when the data were averaged to hourly averages. Between the Specks, the correlation was >0.9 indoors, showing a high degree of reproducibility among the results. The limit of detection was calculated using the method of Wallace et al. (2011) and was found to be 10@?gm -3 at a 99% confidence level for 1-minute data. The mean bias values showed a PM overestimation of 200% for indoor data, and 500% for outdoor data relative to the Grimm values. However, these values are influenced by the low measured PM concentrations. The RMSE of Specks was about 10@?gm -3 and the concentrations were often about this value. The overall precision was 8.8+/-1.7% indoors and 12.2+/-6.2% outdoors, suggesting its independence from changing ambient conditions. The Speck monitors may be suitable for use in indoor and outdoor PM monitoring programs, depending on the required performance to meet the goals of the study. The instrument has a large bias at low concentrations, making it unsuitable for background measurements or for measurements in clean environments. Even at concentrations over the LOD, it is necessary to assess the bias for expected particle sources before any instrument deployment.


  • 주제어

    Particulate matter .   Low cost monitor .   Speck .   Environmental monitoring .   Ambient conditions.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기