본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy v.174, 2017년, pp.86 - 93   SCI SCIE
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

Selective and sensitive fluorimetric determination of carbendazim in apple and orange after preconcentration with magnetite-molecularly imprinted polymer

İlktaç, Raif (Application and Research Center for Testing and Analysis, University of Ege, 35100 Bornova, İzmir, Turkey ) ; Aksuner, Nur (Department of Chemistry, Faculty of Science, University of Ege, 35100 Bornova, İzmir, Turkey ) ; Henden, Emur (Department of Chemistry, Faculty of Science, University of Ege, 35100 Bornova, İzmir, Turkey ) ;
  • 초록  

    Abstract In this study, magnetite-molecularly imprinted polymer has been used for the first time as selective adsorbent before the fluorimetric determination of carbendazim. Adsorption capacity of the magnetite-molecularly imprinted polymer was found to be 2.31±0.63mgg −1 (n=3). Limit of detection (LOD) and limit of quantification (LOQ) of the method were found to be 2.3 and 7.8μgL −1 , respectively. Calibration graph was linear in the range of 10–1000μgL −1 . Rapidity is an important advantage of the method where re-binding and recovery processes of carbendazim can be completed within an hour. The same imprinted polymer can be used for the determination of carbendazim without any capacity loss repeatedly for at least ten times. Proposed method has been successfully applied to determine carbendazim residues in apple and orange, where the recoveries of the spiked samples were found to be in the range of 95.7–103%. Characterization of the adsorbent and the effects of some potential interferences were also evaluated. With the reasonably high capacity and reusability of the adsorbent, dynamic calibration range, rapidity, simplicity, cost-effectiveness and with suitable LOD and LOQ, the proposed method is an ideal method for the determination of carbendazim. Highlights MMIP has been used for the first time for the preconcentration of carbendazim. MMIP can be used repeatedly for quantitative determination of carbendazim. LOD of the method was found to be 2.3μgL −1 . Re-binding and recovery processes are rapid and completed within an hour. Sensitive and selective method for the detection of carbendazim in apple and orange. Graphical abstract [DISPLAY OMISSION]


  • 주제어

    Carbendazim .   Magnetite .   Molecularly imprinted polymer .   Fluorimetric determination.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기