International journal of refrigeration = Revbue internationale du froid v.74, 2017년, pp.385 - 398   SCI SCIE
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

Evaluation de performance d'une pompe A chaleur aErothermique sous des phEnomEnes de dEgivrage non nEcessaires pour neuf villes typiques de la Chine
Performance evaluation of air source heat pump under unnecessary defrosting phenomena for nine typical cities in China

Liu, Jingdong (Corresponding author. Department of Building Environment and Facility Engineering, College of Architecture and Civil Engineering, Beijing University of Technology, No.100 Pingleyuan Road, Chaoyang District, Beijing 100124, China. Fax: +86 010 67393373. ); Sun, Yuying ( ); Wang, Wei ( ); Zhu, Jiahe ( );
  • 초록  

    Abstract Defrosting under unnecessary conditions is a typical and undesirable operating phenomenon for air source heat pump (ASHP). This paper aims to evaluate the ASHP performance under unnecessary defrosting phenomena in different regions of China. Firstly, energy loss for two kinds of unnecessary defrosting phenomena was quantified by 60 days field test. Secondly, a method was developed to predict unnecessary defrosting times. The prediction accuracy can be controlled within 10%. Furthermore, the ASHP performance of unnecessary defrosting was evaluated for nine typical cities in China. It was found that the average unnecessary defrosting rate was 53% for northern cities, 38% for mid-land cities, and 15% for southern cities during a heating season. Correspondingly, the total energy loss was 233 MJkW −1 , 161 MJkW −1 , and 44 MJkW −1 . These results indicate that unnecessary defrosting processes should not have been ignored. It is a valuable work to improve the defrosting control method. Highlights The characteristics of ASHP under unnecessary defrosting phenomena were studied. Energy loss for two kinds of unnecessary defrosting phenomena was quantified. A method was proposed to predict times of unnecessary defrosting operations. Performance loss of unnecessary defrosting was evaluated for typical cities in China. It indicates unnecessary defrosting processes should not have been ignored.


  • 주제어

    Unnecessary defrosting phenomena .   Energy loss .   Performance evaluation .   Air source heat pump .   Phénomènes de dégivrage non nécessaires .   Perte énergétique .   Évaluation de performance .   Pompe à chaleur aérothermique.  