Garcí (Corresponding author. DITF, ETSII, Universidad Polité ); a-Cascales, J.R. (cnica de Cartagena, Dr. Fleming, s/n, Cartagena, Murcia 30202, Spain. Fax: +34 968 325999. ); Illá ( ); n-Gó ( ); mez, F. ( ); Hidalgo-Mompeá ( ); n, F. ( ); Ramí ( ); rez-Rivera, F.A. ( ); Ramí ( ); rez-Basalo, M.A. ( );
  • 초록  

    Abstract This paper reports the results of an experimental and numerical study of the use of a minichannel coil and a fin-and-tube coil in an air/water heat pump working as evaporator when the system is working in heating mode. The experimental installation developed to test the heat pump unit is briefly described and then the experimental results are presented. Alternatively, the heat pump is modelled using a refrigeration system design program. The results obtained using this model are compared to experimental results allowing the validation of the model. Once the model is validated, it is used to numerically determine the distribution of refrigeration charge and other interesting parameters not experimentally measured. Finally, an analysis of the numerically obtained results is presented in order to study the influence of several operating conditions on refrigerant charge, system COP and heating power for both types of evaporators tested. Highlights The performance of an air/water heat pump is experimentally measured. Two different evaporators, minichannel and fin-and-tube coil are compared. Experimental results are used to validate a model developed using a design software. In all cases the refrigerant charge and the efficiency are lower using a minichannel coil. The advantage of replacing a fin-and-tube evaporator by a minichannel evaporator is not clear.


  • 주제어

    Minichannels .   Heat pump .   Refrigerant charge .   Minicanaux .   Pompe à chaleur .   Charge en frigorigène.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기