본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

International journal of refrigeration = Revbue internationale du froid v.74, 2017년, pp.592 - 605   SCI SCIE
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

Comparaison de performances entre une pompe A chaleur combinEe au R134a/CO2 et une pompe A chaleur en cascade au R134a/CO2 pour chauffage de locaux
Performance comparison between the combined R134a/CO2 heat pump and cascade R134a/CO2 heat pump for space heating

Song, Yulong (School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China ); Li, Dongzhe ( School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China ); Yang, Dongfang ( School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China ); Jin, Lei ( School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China ); Cao, Feng ( School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China ); Wang, Xiaolin ( School of Engineering and ICT, University of Tasmania, Hobart, TAS 7001, Australia );
  • 초록  

    Abstract In this paper, the performance of combined R134a/CO 2 and cascade R134a/CO 2 systems for space heating was studied and compared under specific operating conditions. A mathematical model was developed for this purpose and was verified by experimental data. The effects of key parameters such as water feed temperature, water supply temperature and ambient temperature on the performance of the two systems were further investigated. Results showed that cascade and combined systems had different preferable application conditions. The cascade system performed better at low ambient temperatures while the combined system performed better under conditions of high ambient temperature and high hot water temperature differences between the system inlet and outlet. A correlation was established and an operating condition coefficient was proposed to determine which system should be used for any given set of working conditions. Highlights The combined R134a/CO 2 and cascade R134a/CO 2 system was compared and studied. Effect of hot water and ambient temperatures on the two systems was investigated. The two systems showed different preferable operating conditions. A correlation was proposed to identify the system for any given operating condition.


  • 주제어

    Transcritical CO2 heat pump .   Space heating .   R134a/CO2 cascade system .   Performance .   Pompe à chaleur au CO2 transcritique .   Chauffage de locaux .   Système en cascade au R134a/CO2 .   Performance.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기