Clinical biomechanics v.41, 2017년, pp.28 - 33  

Primary stability and viscoelastic displacement of mini-implant system under loading

Lee, J. ; Jeong, Y.H. ; Pittman, J. ; Deguchi, T. ; Johnston, W.M. ; Fields, H.W. ; Kim, D.G. ;
  • 초록  

    Background: The objectives of the current study were to examine the effects of mini-implant diameters on 1) primary stability before bone properties are changed by active peri-implant bone remodeling and 2) the time-dependent displacement of mini-implant systems in bone under a functional radial loading and their associations with bone mineral density. Methods: Twenty one, 8mm length mini-implants (7 each for 1.4mm, 1.6mm, and 2mm diameters) were placed in mandibular sections of human cadavers (4 males and 3 females, average 69.7 (SD 13.1) years of age). Displacement of the mini-implant in wet bone was assessed during initial and subsequent continuous radial loading of 2N in the mediolateral direction for 2h. Mean, standard deviation and coefficient of variation of peri-implant bone mineral density were obtained using histograms of cone-beam computed tomography attenuation values. The cortical thickness along with the miniscrew site was also measured. Findings: The primary stability and displacement of mini-implants in bone were not significantly different between the 3 diameter groups (p>0.147, n=21). Moderate positive correlations of time-dependent viscoelastic displacement (creep) were found with bone mineral density variability independent of the mini-implant diameters (p>0.11). Interpretation: The post-implantation displacements of mini-implant suggested that the orthodontic treatment loading can develop micromotion between the mini-implant and surrounding bone leading to reduction of its primary stability. Current findings also provide an insight that peri-implant bone mineral density variability plays an important role in controlling displacement of the mini-implant, which determine its stability during early and prolonged orthodontic treatment loading periods.


  • 주제어

    Diameter .   Orthodontic loading .   Creep .   Bone mineral density .   Thickness .   Mini-implant.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기