본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

IEEE transactions on bio-medical engineering v.64 no.2, 2017년, pp.352 - 361   SCI SCIE
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

Registration of Multiview Echocardiography Sequences Using a Subspace Error Metric

Peressutti, Devis (Div. of Imaging Sci. & Biomed. Eng., King's Coll. London, London, UK ); Gomez, Alberto (Div. of Imaging Sci. & Biomed. Eng., King's Coll. London, London, UK ); Penney, Graeme P. (Div. of Imaging Sci. & Biomed. Eng., King's Coll. London, London, UK ); King, Andrew P. ( );
  • 초록  

    Objective: 3-D$+t$ echocardiography (3DtE) is widely employed for the assessment of left ventricular anatomy and function. However, the information derived from 3DtE images can be affected by the poor image quality and the limited field of view. Registration of multiview 3DtE sequences has been proposed to compound images from different acoustic windows, therefore improving both image quality and coverage. We propose a novel subspace error metric for an automatic and robust registration of multiview intrasubject 3DtE sequences. Methods: The proposed metric employs linear dimensionality reduction to exploit the similarity in the temporal variation of multiview 3DtE sequences. The use of a low-dimensional subspace for the computation of the error metric reduces the influence of image artefacts and noise on the registration optimization, resulting in fast and robust registrations that do not require a starting estimate. Results: The accuracy, robustness, and execution time of the proposed registration were thoroughly validated. Results on 48 pairwise multiview 3DtE registrations show the proposed error metric to outperform a state-of-the-art phase-based error metric, with improvements in median/75th percentile of the target registration error of 21%/31% and an improvement in mean execution time of 45%. Conclusion: The proposed subspace error metric outperforms sum-of-squared differences and phase-based error metrics for the registration of multiview 3DtE sequences in terms of accuracy, robustness, and execution time. Significance: The use of the proposed subspace error metric has the potential to replace standard image error metrics for a robust and automatic registration of multiview 3DtE sequences.


 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기