본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

IEEE transactions on bio-medical engineering v.64 no.2, 2017년, pp.492 - 498   SCI SCIE
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

Characterization of Axonal Spikes in Cultured Neuronal Networks Using Microelectrode Arrays and Microchannel Devices

Hong, Nari (Department of Bio and Brain EngineeringKorea Advanced Institute of Science and Technology ); Joo, Sunghoon ( Department of Bio and Brain EngineeringKorea Advanced Institute of Science and Technology ); Nam, Yoonkey ( );
  • 초록  

    Objective: Axonal propagation has a pivotal role in information processing in the brain. However, there has been little experimental study due to the difficulty of isolation of axons and recording their signals. Here, we developed dual chamber neuronal network interconnected with axons by integrating microchannel devices with microelectrode arrays (MEAs) to investigate axonal signals in developmental stage. Methods: The device was composed of two chambers and microchannels between them, and hippocampal neurons were cultured in both chambers. Neuronal activity was recorded for four weeks. Results: Large axonal signal was detected in microchannels, which were 137.0 +/- 8.5 mu V at 14 days in vitro (DIV). It was significantly larger than those in chambers with a similar range of signal-to-noise ratio. Detection efficiency of axonal spikes was analyzed by calculating the number of active electrodes over time. We found that active electrodes were detected earlier and their number increased faster in microchannels than those in chambers. Finally, we estimated the axonal conduction velocity and 73% of axons had the velocity in range of 0.2-0.5 m/s at 14 DIV. By estimating the velocity over the cultivation period, we observed that axonal conduction velocity increased linearly over time. Conclusion: Using MEAs and microchannel devices, we successfully detected large axonal signals and analyzed their detection efficiency and conduction velocity. We first showed the gradual increase in conduction velocity depending on cultivation days. Significance: The developed microchannel device integrated MEA may be applicable for the studies of axonal conduction in cultured neuronal networks.


 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기