Mechanisms of Undersensing by a Noise Detection Algorithm That Utilizes Far‐Field Electrograms With Near‐Field Bandpass Filtering

KONERU, JAYANTHI N. (Virginia Commonwealth University/Pauley Heart Center, Richmond, Virginia, USA ) ; SWERDLOW, CHARLES D. (Cedars Sinai Heart Center, Los Angeles, California, USA ) ; PLOUX, SYLVAIN (Bordeaux University Hospital (CHU), Pessac, France ) ; SHARMA, PARIKSHIT S. (Virginia Commonwealth University/Pauley Heart Center, Richmond, Virginia, USA ) ; KASZALA, KAROLY (Hunter Holmes McGuire Veterans Affairs Medical Center, Richmond, Virginia, USA ) ; TAN, ALEX Y. (Hunter Holmes McGuire Veterans Affairs Medical Center, Richmond, Virginia, USA ) ; HUIZAR, JOSE F. (Hunter Holmes McGuire Veterans Affairs Medical Center, Richmond, Virginia, USA ) ; VIJAYARAMAN, PUGAZHENDI (Geisinger Heart Institute, Wilkes‐Barre, Pennsylvania, USA ) ; KENIGSBERG, DAVID (Westside Regional Medical Center, Plantation, Florida, USA ) ; ELLENBOGEN, KENNETH A. (Virgini ) ;
  • 초록  

    Noise Detection Algorithm Pitfalls Background Implantable cardioverter defibrillators (ICDs) must establish a balance between delivering appropriate shocks for ventricular tachyarrhythmias and withholding inappropriate shocks for lead‐related oversensing (“noise”). To improve the specificity of ICD therapy, manufacturers have developed proprietary algorithms that detect lead noise. The SecureSense TM RV Lead Noise discrimination (St. Jude Medical, St. Paul, MN, USA) algorithm is designed to differentiate oversensing due to lead failure from ventricular tachyarrhythmias and withhold therapies in the presence of sustained lead‐related oversensing. Methods and Results We report 5 patients in whom appropriate ICD therapy was withheld due to the operation of the SecureSense algorithm and explain the mechanism for inhibition of therapy in each case. Limitations of algorithms designed to increase ICD therapy specificity, especially for the SecureSense algorithm, are analyzed. Conclusion The SecureSense algorithm can withhold appropriate therapies for ventricular arrhythmias due to design and programming limitations. Electrophysiologists should have a thorough understanding of the SecureSense algorithm before routinely programming it and understand the implications for ventricular arrhythmia misclassification.


  • 주제어

    inappropriate shocks .   SecureSense algorithm .   sensing algorithm .   ventricular tachycardias.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.
유료다운로드

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기