본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

Environmental research v.160, 2018년, pp.20 - 26   SCI SCIE
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

Factors affecting variability in PM2.5 exposure concentrations in a metro system

Li, Zhiyuan (Division of Environment and Sustainability, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China ) ; Che, Wenwei (Division of Environment and Sustainability, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China ) ; Frey, H. Christopher (Division of Environment and Sustainability, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China ) ; Lau, Alexis K.H. (Division of Environment and Sustainability, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China ) ;
  • 초록  

    Abstract The objectives of this study were to: (1) evaluate PM 2.5 inflow to metro train cabins when doors open at stations; (2) assess the spatial and temporal variability in PM 2.5 exposure concentration; and (3) quantify the relationship between in-cabin concentration versus outdoor and non-ambient PM 2.5 . We measured in-cabin PM 2.5 concentrations using portable monitors at the door-side and center of a train cabin simultaneously on a Hong Kong metro line. In addition, platform and in-cabin pollutant concentrations near a train door were simultaneously measured. Short-term spikes in PM 2.5 concentrations typically occur near train doors when doors open, related to inflow of ambient air aboveground and tunnel air underground. In-cabin PM 2.5 exposure concentrations are typically lower away from the doors when the doors open. PM 2.5 concentrations inside train cabins and on station platform operating above-ground are more influenced, compared to underground, by outdoor PM 2.5 . Moreover, non-ambient sources contribute approximately 50% of train in-cabin and station platform PM 2.5 concentrations during underground operation. The results help more accurately quantify commuting PM 2.5 exposure on a metro system, and can be used to improve population-based exposure simulation models. Highlights Door-side PM 2.5 concentrations typically increase when train doors open. Train in-cabin PM 2.5 concentrations are lower than ambient PM 2.5 concentration. Underground metro train in-cabin PM 2.5 concentrations are higher than above-ground. Ambient PM 2.5 infiltration into cabins is higher for above-ground than underground. Non-ambient sources contributed around half of PM 2.5 inside the underground metro.


  • 주제어

    PM2.   5 .   Underground metro .   Above-ground metro .   Train in-cabin .   Station platform .   Hong Kong.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기