본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

Journal of manipulative and physiological therapeutics v.40 no.9, 2017년, pp.685 - 691   SCIE
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

The Reliability of Standing Sagittal Measurements of Spinal Curvature and Range of Motion in Older Women With and Without Hyperkyphosis Using a Skin-Surface Device

Roghani, Tayebeh (Department of Physiotherapy, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran ) ; Khalkhali Zavieh, Minoo (Department of Physiotherapy, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran ) ; Rahimi, Abbas (Department of Physiotherapy, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran ) ; Talebian, Saeed (Department of Physiotherapy, School of Rehabilitation, Tehran University of Medical Sciences and Health Services, Tehran, Iran ) ; Dehghan Manshadi, Farideh (Department of Physiotherapy, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran ) ; Akbarzadeh Baghban, Alireza (Proteomics Research Center, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran ) ; King, Nicole (Department of Physical Therapy and Rehabilitation Sciences, University of California, San Francisco, California ) ; Katzman, Wendy (Department of Physical Therapy and Rehabilitation Sciences, University of California, San Francisco, California ) ;
  • 초록  

    Abstract Objective The purpose of this study was to investigate the intrarater reliability of a skin-surface instrument (Spinal Mouse, Idiag, Voletswil, Switzerland) in measuring standing sagittal curvature and global mobility of the spine in older women with and without hyperkyphosis. Methods Measurements were made in 19 women with hyperkyphosis (thoracic kyphosis angle ≥50°), mean age 67 ± 5 years, and 14 women without hyperkyphosis (thoracic kyphosis angle Results Intraclass correlation coefficients ranged from 0.89 to 0.99 in both groups. The standard errors of measurement ranged from 1.02° to 2.06° in the hyperkyphosis group and from 1.15° to 2.22° in the normal group. The minimal detectable change ranged from 2.85° to 5.73° in the hyperkyphosis group and from 3.20° to 6.17° in the normal group. Conclusions Our results indicated that the Spinal Mouse has excellent intrarater reliability for the measurement of sagittal thoracic and lumbar curvature and mobility of the spine in older women.


  • 주제어

    Spinal Curvatures .   Range of Motion .   Aging .   Kyphosis .   Reliability of Results.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기