Journal of orthodontic science v.1 no.1, 2012년, pp.16 - 22  

Reliable coupling of orthodontic elements to mini-implants: An in-vitro study

Ludwig, Björn    (Department of Orthodontics, University of Homburg / Saar Kirrberger Strasse 1, D- 66421 Homburg / Saar, Germany   ); Zipprich, Holger    (Department of Prosthodontics, Johann Wolfgang Goethe University Frankfurt, Germany   ); Gebel, Britta    (Private Office, Friedhofweg 5, 92676 Eschenbach, Germany   ); Piller, Ben    (Department of Orthodontics, Tel Aviv University, Israel   ); Antoszewska, Joanna    (Department of Dentofacial Orthopedics and Orthodontics, Wroclaw Medical University, Poland  );
  • 초록  

    Objectives: To investigate the reliability of mechanical and adhesive methods of fixing rectangular wires in the cross-slot of a mini-implant. Materials and Methods: A twin-hooked wire element was placed and fixed in the slot of a mini-implant via a NiTi spring under tension, or by means of an adhesive. For the purpose of mechanical anchorage, the wire was crimped with a special crimping tool to increase its thickness and prevent it from slipping through the slot. Before applying the adhesive, there were four possible methods of preparation: Untreated Wire (Adh. 1); ROCATEC-Pre (Adh. 2); ROCATEC-PRE + Espe Sil (Adh. 3); ROCATEC-PRE + ROCATEC-PLUS + Espe Sil (Adh. 4). The mechanical fixing and two adhesive fixings were aged by means of temperature change (500 cycles). A Zwick universal testing machine was used to measure the maximum strength of the coupling. Results: In all tests, the untreated wire + adhesive withstood the lowest maximum load (Ø 3 N and 10.8 N respectively) and failed the aging test after a maximum of eight cycles. The wires in test group Adh. 4 withstood the highest maximum load (Ø 43.3 N; 41.5 N; 45.9 N after aging) in all tests. The average load withstood by the crimped ligature was 38.7 N. Conclusion: The adhesive method of fixation performs best when the rectangular wire is sand blasted and silanized before application. The mechanical coupling using the crimped ligature is reliable.


  • 주제어

    Adhesive .   coupling elements .   cross-slot .   in-vitro experiment .   NiTi spring .   orthodontic mini-implants .   orthodontic wire .   rectangular wire.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기