본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

Sensors and actuators. B, Chemical v.259, 2018년, pp.1013 - 1021   SCI SCIE SCOPUS
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

A microfluidic impedance biosensor based on immunomagnetic separation and urease catalysis for continuous-flow detection of E. coli O157:H7

Yao, Lan (Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture, China Agricultural University, Beijing 100083 China ) ; Wang, Lei (Key Laboratory on Modern Precision Agriculture System Integration Research, Ministry of Education, China Agricultural University, Beijing 100083, China ) ; Huang, Fengchun (Key Laboratory on Modern Precision Agriculture System Integration Research, Ministry of Education, China Agricultural University, Beijing 100083, China ) ; Cai, Gaozhe (Key Laboratory on Modern Precision Agriculture System Integration Research, Ministry of Education, China Agricultural University, Beijing 100083, China ) ; Xi, Xinge (Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, AR 72701, USA ) ; Lin, Jianhan (Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture, China Agricultural University, Beijing 100083 China ) ;
  • 초록  

    Abstract Early screening of foodborne pathogens is a key to control the outbreaks of foodborne illnesses. In this study, a microfluidic impedance biosensor combined with the immune magnetic nanoparticles (MNPs) for bacteria separation, the urease for biological signal amplification and the microfluidic chip for impedance measurement was developed for rapid, sensitive and continuous-flow detection of E. coli O157:H7. After the streptavidin modified MNPs were conjugated with the biotinylated polyclonal antibodies (PAbs) to form the immune MNPs, the target bacteria was first separated by the MNPs from the background to form the MNP-bacteria complexes. Then, the gold nanoparticles (GNPs) modified with the urease and the aptamers against E. coli O157:H7 were conjugated with the MNP-bacteria to form the MNP-bacteria-GNP-urease complexes. Finally, the complexes were used to catalyze the hydrolysis of urea into ammonium carbonate, leading to the decrease in the impedance. The impedance was online measured by this proposed biosensor and analyzed using the impedance normalization to determine the concentration of E. coli O157:H7. A good linear relationship between the impedance relative change rate of the catalysate and the concentration of the bacteria was obtained with low detection limit of 12 CFU/mL. Highlights This biosensor could accurately measure the impedance in continuous-flow condition. The impedance normalization could reduce the impact from microelectrode variation. This biosensor was able to detect E. coli O157:H7 as low as 12 CFU/mL within 2 h. Urease catalysis was used to greatly amplify the detection signal.


  • 주제어

    Impedance biosensor .   Impedance normalization .   Continuous-flow detection .   Immunomagenatic separation .   Urease catalysis.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기