Journal of orthopaedics v.15 no.1, 2018년, pp.67 - 69  

Percutaneous upper extremity fracture fixation using a novel glass-based adhesive

Zalzal, Paul (Oakville Trafalgar Memorial Hospital, Oakville, L6J 3L7, Ontario, Canada ) ; Safir, Oleg (Mount Sinai Hospital, Toronto, M5G 1X5, Ontario, Canada ) ; Alhalawani, Adel (Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, M5B 2K3, Ontario, Canada ) ; Papini, Marcello (Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, M5B 2K3, Ontario, Canada ) ; Towler, Mark (Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, M5B 2K3, Ontario, Canada ) ;
  • 초록  

    Abstract Objective To develop a surgical technique for percutaneous upper extremity fracture fixation using a novel glass-based adhesive. Methods Three intact upper extremity cadaveric specimens with undisturbed soft tissues were obtained. Two were used to model a wrist fracture, and the third to model a proximal humerus fracture. Fractures were produced using a small osteotome in a percutaneous fashion. Banna Bone Adhesive (BBA) was delivered to the fracture site percutaneously using a 16 gauge needle under bi-planar fluoroscopic guidance. After setting of the adhesive, the specimens were dissected to qualitatively assess BBA delivery and placement. Results The adhesive could readily be delivered through the 16 gauge needle with an appropriate amount of pressure applied to the syringe. Using the fluoroscope, the adhesive could be seen to flow into the fracture site with minimal extravagation into the surrounding soft tissues. Successful bonding of the fracture fragments was observed. Conclusions Percutaneous delivery of BBA into a fracture of the distal radius and proximal humerus may be a feasible fracture fixation technique. Biomechanical testing and animal model testing are required to further develop this procedure.


  • 주제어

    Fracture fixation .   Glass polyalkanoate cement .   Wrist fracture .   Humerus fracture .   Injectable adhesive .   Bioactive glass .   Surgery .   Minimally invasive.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기