Metrological characterization of a combined bio-impedance plethysmograph and spectrometer

Pittella, Erika (Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy ) ; Piuzzi, Emanuele (Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy ) ; Rizzuto, Emanuele (Department of Mechanical and Aerospace Engineering, Sapienza University of Rome, 00184 Rome, Italy ) ; Pisa, Stefano (Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy ) ; Del Prete, Zaccaria (Department of Mechanical and Aerospace Engineering, Sapienza University of Rome, 00184 Rome, Italy ) ;
  • 초록  

    Abstract In this paper, the design and characterization of a device, able to analyze the electrical bio-impedance in the frequency domain and its variations with time, is presented. The whole system design, that employs a tetra-polar electrode configuration, a specifically developed printed circuit board, and a data acquisition card connected to a PC, is presented. The measurement system is controlled through LabVIEW virtual instruments. Different reference resistors and RC networks, with impedance values lying in the physiological range of bio-impedances, have been used for assessing the systematic and random uncertainty contributions, and to derive the calibration curves necessary to correct the systematic effects of the developed instrument. The obtained results show that it is possible to achieve excellent metrological performances with the proposed system, that is suitable to be developed in a low-cost and portable version. Two possible applications of the instrument are shown, i.e. cardio-respiratory activity monitoring and bioelectrical impedance spectroscopy. Highlights Development of a measurement device for time and frequency-domain bio-impedance analyses. Device metrological characterization and systematic error correction. Achieved accuracy after systematic error correction comparable to a benchtop precision LCR meter. Experimental results for cardio-respiratory activity monitoring and bioelectrical impedance spectroscopy.


  • 주제어

    Bioelectrical impedance spectroscopy .   Bioimpedance .   Measurement uncertainty .   Plethysmography .   Portable device.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기