Normal reference ranges for aortic diameters in preterm infants

Abushaban, Lulu (Chest Diseases Hospital, Ministry of Health, Kuwait City, KuwaitaKuwait ) ; Mariappa, Thinakar Vel (Chest Diseases Hospital, Ministry of Health, Kuwait City, KuwaitaKuwait ) ; Rathinasamy, Jebaraj (Chest Diseases Hospital, Ministry of Health, Kuwait City, KuwaitaKuwait ) ; Sharma, Prem N. (Faculty of Medicine, Health Sciences Center, Kuwait University, Kuwait City, KuwaitcKuwait ) ;
  • 초록  

    Abstract Objective To establish normal reference ranges and Z -scores for aortic diameters in preterm infants according to the body surface area and assess their correlation with body weight, body surface area, and gestational age. Patients and methods In a prospective study, 268 preterm infants who fulfilled the criteria for inclusion were examined. Echocardiograms were performed to measure the ascending aorta, transverse aorta, and aortic isthmus diameters on 0 days to 6 days of life and at weekly intervals until the babies reached 36 weeks. Body surface area was divided into 13 groups from 0.07 m 2 to 0.19 m 2 . Results The mean gestational age was 29.8 [± 2.38 standard deviation (SD)] weeks, ranging from 24 weeks to 35 weeks. The mean body weight was 1479 (± 413 SD) g, ranging from 588 g to 3380 g, and the mean body surface area was 0.13 m 2 , ranging from 0.07 m 2 to 0.19 m 2 . All the aortic diameters correlated well with both body weight and body surface area. Reference ranges with the mean ± SD, range, and Z -scores were calculated for aortic diameters according to the body surface area. A significant gradual increase was observed in ascending aorta, transverse aorta, and aortic isthmus diameters with increasing body surface area. Overall, a progressive and significant increase in ascending aorta, transverse aorta, and aortic isthmus diameters was observed during the first 9 weeks of life. Conclusion The ascending aorta, transverse aorta, and aortic isthmus diameters exhibited a significant correlation with the body surface area and body weight. This study provides reference data with Z -scores that can be used as a normal reference tool for the ascending aorta, transverse aorta, and aortic isthmus diameters for preterm infants based on the body surface area.


  • 주제어

    Aortic diameters .   Body surface area .   Preterm infants .   Reference ranges .   Z-scores.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기