본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

International journal of electrical power & energy systems v.99, 2018년, pp.474 - 480   SCIE
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

A novel traveling-wave-based protection scheme for LCC-HVDC systems using Teager Energy Operator

Hao, Wang    (Shaanxi Key Laboratory of Smart Grid, Department of Electrical Engineering, Xi'an Jiaotong University, Shaanxi, People's Republic of China   ); Mirsaeidi, Sohrab    (Department of Electrical Engineering, Tsinghua University, Beijing, People's Republic of China   ); Kang, Xiaoning    (Shaanxi Key Laboratory of Smart Grid, Department of Electrical Engineering, Xi'an Jiaotong University, Shaanxi, People's Republic of China   ); Dong, Xinzhou    (Department of Electrical Engineering, Tsinghua University, Beijing, People's Republic of China   ); Tzelepis, Dimitrios    (Department of Electronic & Electrical Engineering, Strathclyde University, Glasgow, United Kingdom  );
  • 초록  

    Abstract Line Commutated Converter (LCC) based High-Voltage Direct Current (HVDC) technology has been in operation with a high level reliability and little maintenance requirements for more than thirty years. The current-source based or classical LCC-HVDC systems are being considered for buried cable transmission as well as overhead transmission. The fault analysis and protection of LCC-HVDC system is a very important aspect in terms of power system stability. This paper proposes a novel protection scheme for LCC-HVDC systems, in which the difference between propagation processes of traveling wave under internal and external faults is used as a criterion for detection of fault incidents in HVDC transmission lines. In order to quantify and intensify this difference, Teager Energy Operator (TEO) is used which has the ability to reflect the instantaneous energy of a signal. The main feature of the proposed scheme in comparison with the existing ones is that it operates faster, since it does not require to extract any harmonic or high frequency component; moreover, a 2-ms sampling window is sufficient for its algorithm which only deals with simple calculations. In order to validate the effectiveness of the proposed protection scheme, several fault events under different fault resistances and fault locations were simulated on a test network using PSCAD/EMTDC software. Also, the performance of the proposed scheme under real fault events was tested using four field data cases. Both simulation data and field data test results indicated that the proposed protection strategy has the ability to accurately discriminate between internal and external faults and detect the faulted pole in the bipolar systems even under high-impedance fault conditions. Highlights This paper proposes a new traveling-wave-based protection scheme for LCC-HVDC Systems. TEO is also used which has the ability to reflect the instantaneous energy of a signal. This scheme operates fast, since it does not need to extract any frequency component.


  • 주제어

    HVDC transmission line .   Traveling wave protection .   Teager Energy Operator.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기