Shake‐table test performance of an inertial force‐limiting floor anchorage system

Zhang, Zhi (Thornton Tomasetti, New York, NY, USA ) ; Fleischman, Robert B. (Department of Civil Engineering and Engineering Mechanics, University of Arizona, Tucson, AZ, USA ) ; Restrepo, Jose I. (Department of Structural Engineering, UCSD, La Jolla, CA, USA ) ; Guerrini, Gabriele (Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy ) ; Nema, Arpit (Department of Structural Engineering, UCSD, La Jolla, CA, USA ) ; Zhang, Dichuan (Nazarbayev University, Astana, Republic of Kazakhstan ) ; Shakya, Ulina (CEEM Department, University of Arizona, Tucson, AZ, USA ) ; Tsampras, Georgios (Simpson Gumpertz & Heger Inc., Waltham, MA, USA ) ; Sause, Richard (ATLSS Engineering Research Center, Department of Civil and Environmental Engineering, Lehigh University, Bethlehem, PA, USA ) ;
  • 초록  

    Summary A new floor connecting system developed for low‐damage seismic‐resistant building structures is described herein. The system, termed Inertial Force‐Limiting Floor Anchorage System (IFAS), is intended to limit the lateral forces in buildings during an earthquake. This objective is accomplished by providing limited‐strength deformable connections between the floor system and the primary elements of the lateral force‐resisting system. The connections transform the seismic demands from inertial forces into relative displacements between the floors and lateral force‐resisting system. This paper presents the IFAS performance in a shake‐table testing program that provides a direct comparison with an equivalent conventional rigidly anchored‐floor structure. The test structure is a half‐scale, 4‐story reinforced concrete flat‐plate shear wall structure. Precast hybrid rocking walls and special precast columns were used for test repeatability in a 22‐input strong ground‐motion sequence. The structure was purposely designed with an eccentric wall layout to examine the performance of the system in coupled translational‐torsional response. The test results indicated a seismic demand reduction in the lateral force‐resisting system of the IFAS structure relative to the conventional structure, including reduced shear wall base rotation, shear wall and column inter‐story drift, and, in some cases, floor accelerations. These results indicate the potential for the IFAS to minimize damage to the primary structural and non‐structural components during earthquakes.


  • 주제어

    earthquake engineering .   floor isolation system .   inertial force limiting .   low‐damage system .   seismic response reduction .   shake‐table testing.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.
유료다운로드

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기