본문 바로가기
HOME> 논문 > 논문 검색상세

논문 상세정보

Macromolecular bioscience v.18 no.7, 2018년, pp.1700292 -   

Development of a Polymer‐Based Biodegradable Neurovascular Stent Prototype: A Preliminary In Vitro and In Vivo Study

Nikoubashman, Omid (Department of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany ) ; Heringer, Sarah (Department of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany ) ; Feher, Katalin (Institute of Tissue Engineering and Textile Implants, RWTH Aachen University, Otto‐Blumenthal‐Str. 1, 52074, Aachen, Germany ) ; Brockmann, Marc‐Alexander (Department of Diagnostic and Interventional Neuroradiology, University Hospital Mainz, 55131, Mainz, Germany ) ; Sellhaus, Bernd (Institute of Neuropathology, University Hospital, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany ) ; Dreser, Alice (Institute of Neuropathology, University Hospital, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany ) ; Kurtenbach, Kathrin ; Pjontek, Rastislav ; Jockenhövel, Stefan ; Weis, Joachim ; Kießling, Fabian ; Gries, Thomas ; Wiesmann, Martin ;
  • 초록  

    Abstract Biodegradable stents are not established in neurovascular interventions. In this study, mechanical, radiological, and histological characteristics of a stent prototype developed for neurovascular use are presented. The elasticity and brittleness of PLA 96/4, PLDL 70/30, PCL, and PLGA 85/15 and 10/90 polymers in in vitro experiments are first analyzed. After excluding the inapt polymers, degradability and mechanical characteristics of 78 PLGA 85/15 and PLGA 10/90 stent prototypes are analyzed. After excluding PLGA 10/90 stents because of rapid loss of mass PLGA 85/15 stents in porcine in vivo experiments are analyzed. Angiographic occlusion rates 7 d, 1 month, 3 months, and 6 months after stent implantation are assessed. Histological outcome measures are the presence of signs of inflammation, endothelialization, and the homogeneity of degradation after six months. One case of stent occlusion occurs within the first 7 d. There is a prominent foreign‐body reaction with considerable mononuclear and minor granulocytic inflammation combined with incomplete fragmental degradation of the struts. It is possible to produce a stent prototype with dimensions that fit the typical size of carotid arteries. Major improvements concerning thrombogenicity, degradation, and inflammatory response are required to produce biodegradable stents that are suitable for neurovascular interventions.


  • 주제어

    biodegradable polymers .   bioresorbable .   neurovascular .   PLGA .   stent.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.
유료다운로드

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기