Coupling trapped ion mobility spectrometry to mass spectrometry: trapped ion mobility spectrometry–time‐of‐flight mass spectrometry versus trapped ion mobility spectrometry–Fourier transform ion cyclotron resonance mass spectrometry

Tose, Lilian V. (Federal University of Espírito Santo, Petroleomic and Forensic Chemistry Laboratory, Department of Chemistry, 29075‐910, Vitória, ES, Brazil ) ; Benigni, Paolo (Florida International University, Department of Chemistry and Biochemistry, Miami, FL, 33199, USA ) ; Leyva, Dennys (Florida International University, Department of Chemistry and Biochemistry, Miami, FL, 33199, USA ) ; Sundberg, Abigail (Florida International University, Department of Chemistry and Biochemistry, Miami, FL, 33199, USA ) ; Ramírez, César E. (Florida International University, Department of Chemistry and Biochemistry, Miami, FL, 33199, USA ) ; Ridgeway, Mark E. (Bruker Daltonics Inc., Billerica, MA, 01821, USA ) ; Park, Melvin A. (Bruker Daltonics Inc., Billerica, MA, 01821, USA ) ; Romão, Wanderson (Federal University of Espírito Santo, Petroleomic and F ) ; Jaffé, Rudolf ; Fernandez‐Lima, Francisco ;
  • 초록  

    Rationale There is a need for fast, post‐ionization separation during the analysis of complex mixtures. In this study, we evaluate the use of a high‐resolution mobility analyzer with high‐resolution and ultrahigh‐resolution mass spectrometry for unsupervised molecular feature detection. Goals include the study of the reproducibility of trapped ion mobility spectrometry (TIMS) across platforms, applicability range, and potential challenges during routine analysis. Methods A TIMS analyzer was coupled to time‐of‐flight mass spectrometry (TOF MS) and Fourier transform ion cyclotron resonance mass spectrometry (FT‐ICR MS) instruments for the analysis of singly charged species in the m / z 150–800 range of a complex mixture (Suwannee River Fulvic Acid Standard). Molecular features were detected using an unsupervised algorithm based on chemical formula and IMS profiles. Results TIMS‐TOF MS and TIMS‐FT‐ICR MS analysis provided 4950 and 7760 m / z signals, 1430 and 3050 formulas using the general C x H y N 0–3 O 0–19 S 0–1 composition, and 7600 and 22 350 [ m / z ; chemical formula; K; CCS] features, respectively. Conclusions TIMS coupled to TOF MS and FT‐ICR MS showed similar performance and high reproducibility. For the analysis of complex mixtures, both platforms were able to capture the major trends and characteristics; however, as the chemical complexity at the level of nominal mass increases with m / z ( m / z >300–350), only TIMS‐FT‐ICR MS was able to report the lower abundance compositional trends.


 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
  • 원문이 없습니다.
유료다운로드

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기