Time to correct the flow of corrected flow time

Barjaktarevic, Igor    (Division of Pulmonary and Critical Care Medicine, David Geffen School of Medicine at University of California, Los Angeles, USA   ); Chiem, Alan    (Department of Emergency Medicine, Olive View-UCLA Medical Center, University of California, Los Angeles, USA   ); Cannesson, Maxime    (Department of Anesthesiology, David Geffen School of Medicine at University of California, Los Angeles, USA  );
  • 초록  

    Recently published study of Ma et al. evaluates two relatively novel measures of fluid responsiveness, carotid blood flow and corrected carotid flow time (ccFT). Both measures have been recently quoted as possibly useful, technically simple, and noninvasive dynamic tools in predicting fluid responsiveness. Recently, more research interest has been focused on ccFT and, intrigued by the data presented in this study, we discuss here the impact of the data presented in the paper of Ma et al. to the significance of this metric as a potential tool in the assessment of fluid responsiveness.


  • 주제어

    Corrected flow time .   Carotid corrected flow time .   Fluid responsiveness .   Shock .   Critical care ultrasound.  