Ultrasonography v.37 no.2, 2018년, pp.140 - 148   SCOPUS
본 등재정보는 저널의 등재정보를 참고하여 보여주는 베타서비스로 정확한 논문의 등재여부는 등재기관에 확인하시기 바랍니다.

Does standoff material affect acoustic radiation force impulse elastography? A preclinical study of a modified elastography phantom

Hollerieth, Katharina    (Department of Nephrology, Klinikum Rechts der Isar of the Technical University of Munich, Munich, Germany  ); Gaßmann, Bernhard    (Meso International GmbH, Mittweida/Berlin, Germany  ); Wagenpfeil, Stefan    (Institute for Medical Biometry, Epidemiology and Medical Informatics, Saarland University, Campus Homburg, Homburg, Saar, Germany  ); Kemmner, Stephan    (Department of Nephrology, Klinikum Rechts der Isar of the Technical University of Munich, Munich, Germany  ); Heemann, Uwe    (Department of Nephrology, Klinikum Rechts der Isar of the Technical University of Munich, Munich, Germany  ); Stock, Konrad Friedrich    (Department of Nephrology, Klinikum Rechts der Isar of the Technical University of Munich, Munich, Germany  );
  • 초록

    Purpose This study was conducted to determine the influence of standoff material on acoustic radiation force impulse (ARFI) measurements in an elasticity phantom by using two different probes. Methods Using ARFI elastography, 10 observers measured the shear wave velocity (SWV, m/sec) in different lesions of an elasticity phantom with a convex 4C1 probe and a linear 9L4 probe. The experimental setup was expanded by the use of an interposed piece of porcine muscle as standoff material. The probe pressure on the phantom was registered. Results Faulty ARFI measurements occurred more often when quantifying the hardest lesion (74.0 kPa 4.97 m/sec) by the 9L4 probe with the porcine muscle as a standoff material interposed between the probe and the phantom. The success rate for ARFI measurements in these series was 52.4%, compared with 99.5% in the other series. The SWV values measured with the 9L4 probe were significantly higher (3.33±1.39 m/sec vs. 2.60±0.74 m/sec, P Conclusion The presence of porcine muscle acting as a standoff material influenced the occurrence of failed measurements as well as the variance and the accuracy of the measured values. The linear high-frequency probe was particularly affected.


  • 주제어

    Elasticity imaging techniques .   Ultrasonography .   Standoff material .   Muscles .   Transducers.  

 활용도 분석

  • 상세보기

    amChart 영역
  • 원문보기

    amChart 영역

원문보기

무료다운로드
유료다운로드
  • 원문이 없습니다.

유료 다운로드의 경우 해당 사이트의 정책에 따라 신규 회원가입, 로그인, 유료 구매 등이 필요할 수 있습니다. 해당 사이트에서 발생하는 귀하의 모든 정보활동은 NDSL의 서비스 정책과 무관합니다.

원문복사신청을 하시면, 일부 해외 인쇄학술지의 경우 외국학술지지원센터(FRIC)에서
무료 원문복사 서비스를 제공합니다.

NDSL에서는 해당 원문을 복사서비스하고 있습니다. 위의 원문복사신청 또는 장바구니 담기를 통하여 원문복사서비스 이용이 가능합니다.

이 논문과 함께 출판된 논문 + 더보기