본문 바로가기
HOME> 저널/프로시딩 > 저널/프로시딩 검색상세

저널/프로시딩 상세정보

권호별목차 / 소장처보기

H : 소장처정보

T : 목차정보

Journal of the Illuminating Engineering Society 16건

  1. [해외논문]   INTERACTION BETWEEN FIXED AND VEHICULAR ILLUMINATION SYSTEMS ON CITY STREETS  

    Gallagher, V. P. (Franklin Inst Res Lab, Philadelphia, Pa) , Janoff, N. S. , Farber, E.
    Journal of the Illuminating Engineering Society v.4 no.1 ,pp. 3 - 10 , 1974 , 0099-4480 ,

    초록

    Drivers' responses to a roadway obstacle almost always improved in the presence of increased illumination or uniformity. This performance improvement became asymptotic at an illumination level below 2. 5 average horizontal footcandles but above 0. 4 fc. This relationship was maintained even with the inclusion of daylight driving performance. The effect of increased non-uniformity was always a decrease in target detection performance but this was not found to be linear.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  2. [해외논문]   LAMPS FOR ASSESSING METAMERISM  

    Thornton, W. A. (Westinghouse Electr Corp, Bloomfield, NJ)
    Journal of the Illuminating Engineering Society v.4 no.1 ,pp. 11 - 18 , 1974 , 0099-4480 ,

    초록

    Even if commercial products such as automobile paint and upholstery match in color and lightness under daylight illumination, they often mismatch under some of the many other common illuminants. Both paint and upholstery possess a spectral reflectance curve with a per cent of light reflected at each wavelength through the visible spectrum. Reflectance differences in certain particular wavelength regions are the troublemakers in such a mismatch. New fluorescent lamps emit in these wavelength regions. By causing about the worst possible mismatch, the new lamps give a dependable estimate of potential trouble with matching colors, and can indicate where the trouble lies. Conversely, prime-color fluorescent lamps have the peculiar capability of preserving a match prepared in daylight.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  3. [해외논문]   OBSERVATIONS ON ELECTROMIGRATION AND IMPROVED FILAMENT LIFE OF MICROMINIATURE LAMPS  

    Koo, R. C. (Duro-Test Corp, North Bergen, NJ) , Woodhouse, John
    Journal of the Illuminating Engineering Society v.4 no.1 ,pp. 19 - 24 , 1974 , 0099-4480 ,

    초록

    Longer lamp life can be achieved by improving the vacuum during exhaust. Experimental results show that early burn-out of filaments heated by dc is preceded by extensive twist and distortion of the filaments causing localized over-heating. Filament instability results from the thermal stresses developed by extensive notch formation due to differential rates of electromigration of tungsten atoms on the filament surfaces along various crystallographic planes. By improving the vacuum, notching and twisting of the filament are minimized with a subsequent seven-fold increase in filament life.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  4. [해외논문]   Absolute Color Rendering  

    Jerome, C. W.
    Journal of the Illuminating Engineering Society v.4 no.1 ,pp. 25 - 28 , 1974 , 0099-4480 ,

    초록

    Longer lamp life can be achieved by improving the vacuum during exhaust. Experimental results show that early burn-out of filaments heated by dc is preceded by extensive twist and distortion of the filaments causing localized over-heating. Filament instability results from the thermal stresses developed by extensive notch formation due to differential rates of electromigration of tungsten atoms on the filament surfaces along various crystallographic planes. By improving the vacuum, notching and twisting of the filament are minimized with a subsequent seven-fold increase in filament life.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  5. [해외논문]   Fluorescent Lamp Starting Aids—How and Why They Work  

    Roche, William J. , Milke, Howard W.
    Journal of the Illuminating Engineering Society v.4 no.1 ,pp. 29 - 36 , 1974 , 0099-4480 ,

    초록

    Longer lamp life can be achieved by improving the vacuum during exhaust. Experimental results show that early burn-out of filaments heated by dc is preceded by extensive twist and distortion of the filaments causing localized over-heating. Filament instability results from the thermal stresses developed by extensive notch formation due to differential rates of electromigration of tungsten atoms on the filament surfaces along various crystallographic planes. By improving the vacuum, notching and twisting of the filament are minimized with a subsequent seven-fold increase in filament life.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  6. [해외논문]   FLUORESCENT LAMP STARTING AIDS EM DASH HOW AND WHY THEY WORK  

    Roche, William J. ; Milke, Howard W.
    Journal of the Illuminating Engineering Society v.4 no.1 ,pp. 29 - 36 , 1974 , 0099-4480 ,

    초록

    Envisioning all the constituent parts of the fluorescent lamp as being a starting aid (either positive or negative), an explanation of the effect of each of these components is given EM DASH with emphasis placed on the effect of the bulb wall resistance on the starting process. The advent of conductive coatings and stripes has expanded the options available to the lamp designer in terms of fill gas and pressure range. This, in turn, could lead to the development of more efficient and lower energy consuming lamps which could be operated on existing ballast circuits.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  7. [해외논문]   RADIANT FLUX MEASUREMENTS OF ULTRAVIOLET EMITTING LIGHT SOURCES  

    Spears, G. R. (GTE Sylvania, Danvers, Mass)
    Journal of the Illuminating Engineering Society v.4 no.1 ,pp. 36 - 42 , 1974 , 0099-4480 ,

    초록

    Measurements have been conducted and data have been available on radiant flux measurements of ultraviolet light sources for many years. However, there was a high degree of uncertainty in the results below 300 nanometers. The most recent NBS standard of spectral irradiance permits measurements to be conducted in the 250- to 315-nanometer region with greater confidence. This paper describes a procedure for obtaining precise measurements of spectral irradiance and spectral radiant flux in the ultraviolet region.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  8. [해외논문]   MEASUREMENT OF ULTRAVIOLET IRRADIANCE FROM ILLUMINANTS IN TERMS OF PROPOSED PUBLIC HEALTH STANDARDS  

    Bickford, E. D. (GTE Sylvania Light Cent, Danvers, Mass) , Clark, G. W. , Spears, G. R.
    Journal of the Illuminating Engineering Society v.4 no.1 ,pp. 43 - 48 , 1974 , 0099-4480 ,

    초록

    Accurate measurements of irradiance from sources are a critical parameter in the determination of hazard threshold energy levels established for the 200- to 315-nm wavelength region. Meters designed for this purpose had significant errors attributed to mismatch between proposed hazard response curve and the response of the photometer detector. Based upon calculations it was determined that the proposed standard was more restrictive than previous ultraviolet standards. The proposed standard would limit illuminance from illuminants to 52 footcandles for cool white fluorescent, 23 footcandles for tungsten-halogen, 47 footcandles for metal halide and 1. 5 footcandles for mercury, considering that the irradiance is wholly from the lamp and not altered by luminaire or room reflectances. 17 refs.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  9. [해외논문]   A Validation of the Color-Preference Index  

    Thornton, W. A.
    Journal of the Illuminating Engineering Society v.4 no.1 ,pp. 48 - 52 , 1974 , 0099-4480 ,

    초록

    Accurate measurements of irradiance from sources are a critical parameter in the determination of hazard threshold energy levels established for the 200- to 315-nm wavelength region. Meters designed for this purpose had significant errors attributed to mismatch between proposed hazard response curve and the response of the photometer detector. Based upon calculations it was determined that the proposed standard was more restrictive than previous ultraviolet standards. The proposed standard would limit illuminance from illuminants to 52 footcandles for cool white fluorescent, 23 footcandles for tungsten-halogen, 47 footcandles for metal halide and 1. 5 footcandles for mercury, considering that the irradiance is wholly from the lamp and not altered by luminaire or room reflectances. 17 refs.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  10. [해외논문]   VALIDATION OF THE COLOR-PREFERENCE INDEX  

    Thornton, W. A.
    Journal of the Illuminating Engineering Society v.4 no.1 ,pp. 48 - 52 , 1974 , 0099-4480 ,

    초록

    Four fluorescent lamps of daylight chromaticity, and with varying Color-Preference Index (CPI), illuminated an array of fruit, vegetables, breads and meat. The lamps were rated in order of preference for the coloration of this array by 267 observers. Excellent correlation of observer preference with CPI, as well as with the prime-color content of the spectral power distributions of the lamps, served to validate the CPI and Judd's assignment of preferred chromaticities of identifiable objects. 22 refs.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지

논문관련 이미지