  1. [해외논문]   Special Issue: Microfluidic Lab-on-a-Chip Platforms for High-Performance Diagnostics  

    Ducré , e, Jens
    Diagnostics v.2 no.4 ,pp. 1 - 1 , 2012 ,

    초록

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  2. [해외논문]   Intra-/Interobserver Agreement of Enhancement Pattern for Pancreatic Head Lesions Using Contrast-Enhanced Ultrasound: According to EFSUMB Guidelines  

    Grossjohann, Hanne Sønder , Ewertsen, Caroline , Svendsen, Lars Bo , Nielsen, Michael Bachmann
    Diagnostics v.2 no.4 ,pp. 2 - 9 , 2012 ,

    초록

    Objectiv e: To evaluate the intra-/interobserver agreement of the visual interpretation of contrast-enhanced ultrasound (CEUS) of pancreatic head lesions and its concordance with the histological test results. Material and Methods : Two observers (A + B) evaluated by simple visual interpretation 40 consecutive CEUS examinations of pancreatic head lesions and one of the observers evaluated the examinations twice (A1 + A2). The examinations were evaluated according to the criteria outlined in EFSUMB guidelines. The two experienced observers were blinded to histological evidence and clinical information of tumor type and to each other's results. Results : The kappa value for the intraobserver evaluation between observer A1 and A2 was 0.89, equating to almost perfect agreement. The kappa value for the interobserver evaluation between observer A1 and B was 0.76 and between observer A2 and B it was 0.75, both equating to substantial agreement. Evaluation of the visual interpretation compared to the histological test result showed a positive predictive value for A1, A2 and B versus biopsy of 97%, 94% and 90% respectively and an accuracy of 83%, 88% and 73% respectively. Conclusions : Visual interpretation for assessment of contrast enhancement of pancreatic head lesions seemed to be an accurate method with reproducible results and good concordance with the histological test results.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  3. [해외논문]   The Combination of In vivo 124 I-PET and CT Small Animal Imaging for Evaluation of Thyroid Physiology and Dosimetry  

    El-Ali, Henrik H. (Cluster for Molecular Imaging, Faculty of Health Sciences, University of Copenhagen, Copenhagen DK-2200, Denmark) , Eckerwall, Martin (E-Mails: dskovgaard@hotmail.com (D.S.)) , Skovgaard, Dorthe (akjaer@sund.ku.dk (A.K.) ) , Larsson, Erik (Medical Radiation Physics, Department of Clinical Sciences, University of Lund, Lund SE-221 85, Sweden) , Strand, Sven-Erik (E-Mails: martin.eckerwall@siemens.com (M.E.)) , Kjaer, Andreas (erik.larsoon@med.lu.se (E.L.))
    Diagnostics v.2 no.4 ,pp. 10 - 22 , 2012 ,

    초록

    Objective: A thyroid rat model combining functional and anatomical information would be of great benefit for better modeling of thyroid physiology and for absorbed dose calculations. Our aim was to show that 124 I-PET and CT small animal imaging are useful as a combined model for studying thyroid physiology and dose calculation. Methods : Seven rats were subjects for multiple thyroid 124 I-imaging and CT-scans. S-values [mGy/MBqs] for different thyroid sizes were simulated. A phantom with spheres was designed for validation of performances of the small animal PET and CT imaging systems. Results: Small animal image-based measurements of the activity amount and the volumes of the spheres with a priori known volumes showed a good agreement with their corresponding actual volumes. The CT scans of the rats showed thyroid volumes from 34–70 mL. Conclusions: The wide span in volumes of thyroid glands indicates the importance of using an accurate volume-measuring technique such as the small animal CT. The small animal PET system was on the other hand able to accurately estimate the activity concentration in the thyroid volumes. We conclude that the combination of the PET and CT image information is essential for quantitative thyroid imaging and accurate thyroid absorbed dose calculation.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  4. [해외논문]   Comparison of 1-Ethyl-3-(3-Dimethylaminopropyl) Carbodiimide Based Strategies to Crosslink Antibodies on Amine-Functionalized Platforms for Immunodiagnostic Applications  

    Vashist, Sandeep Kumar (Centre for Bioanalytical Sciences, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland)
    Diagnostics v.2 no.4 ,pp. 23 - 33 , 2012 ,

    초록

    1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) alone, and in combination with N-hydroxysuccinimide (NHS) or sulfoNHS were employed for crosslinking anti-human fetuin A (HFA) antibodies on 3-aminopropyltriethoxysilane (APTES)-functionalized surface plasmon resonance (SPR) gold chip and 96-well microtiter plate. The SPR immunoassay and sandwich enzyme linked immunosorbent immunoassay (ELISA) for HFA clearly demonstrated that EDC crosslinks anti-HFA antibodies to APTES-functionalized bioanalytical platforms more efficiently than EDC/NHS and EDC/sulfoNHS at a normal pH of 7.4. Similar results were obtained by sandwich ELISAs for human Lipocalin-2 and human albumin, and direct ELISA for horseradish peroxidase. The more efficient crosslinking of antibodies by EDC to the APTES-functionalized platforms increased the cost-effectiveness and analytical performance of our immunoassays. This study will be of wide interest to researchers developing immunoassays on APTES-functionalized platforms that are being widely used in biomedical diagnostics, biosensors, lab-on-a-chip and point-of-care-devices. It stresses a critical need of an intensive investigation into the mechanisms of EDC-based amine-carboxyl coupling under various experimental conditions.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  5. [해외논문]   Improving Accuracy for Image Fusion in Abdominal Ultrasonography  

    Ewertsen, Caroline , Hansen, Kristoffer L. , Henriksen, Birthe M. , Nielsen, Michael B.
    Diagnostics v.2 no.4 ,pp. 34 - 41 , 2012 ,

    초록

    Image fusion involving real-time ultrasound (US) is a technique where previously recorded computed tomography (CT) or magnetic resonance images (MRI) are reformatted in a projection to fit the real-time US images after an initial co-registration. The co-registration aligns the images by means of common planes or points. We evaluated the accuracy of the alignment when varying parameters as patient position, respiratory phase and distance from the co-registration points/planes. We performed a total of 80 co-registrations and obtained the highest accuracy when the respiratory phase for the co-registration procedure was the same as when the CT or MRI was obtained. Furthermore, choosing co-registration points/planes close to the area of interest also improved the accuracy. With all settings optimized a mean error of 3.2 mm was obtained. We conclude that image fusion involving real-time US is an accurate method for abdominal examinations and that the accuracy is influenced by various adjustable factors that should be kept in mind.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  6. [해외논문]   Importance of Attenuation Correction (AC) for Small Animal PET Imaging  

    El Ali, Henrik H. , Bodholdt, Rasmus Poul , Jørgensen, Jesper Tranekjær , Myschetzky, Rebecca , Kjaer, Andreas
    Diagnostics v.2 no.4 ,pp. 42 - 51 , 2012 ,

    초록

    The purpose of this study was to investigate whether a correction for annihilation photon attenuation in small objects such as mice is necessary. The attenuation recovery for specific organs and subcutaneous tumors was investigated. A comparison between different attenuation correction methods was performed. Methods : Ten NMRI nude mice with subcutaneous implantation of human breast cancer cells (MCF-7) were scanned consecutively in small animal PET and CT scanners (MicroPET TM Focus 120 and ImTek's MicroCAT TM II). CT-based AC, PET-based AC and uniform AC methods were compared. Results: The activity concentration in the same organ with and without AC revealed an overall attenuation recovery of 9–21% for MAP reconstructed images, i.e. , SUV without AC could underestimate the true activity at this level. For subcutaneous tumors, the attenuation was 13 ± 4% (9–17%), for kidneys 20 ± 1% (19–21%), and for bladder 18 ± 3% (15–21%). The FBP reconstructed images showed almost the same attenuation levels as the MAP reconstructed images for all organs. Conclusions: The annihilation photons are suffering attenuation even in small subjects. Both PET-based and CT-based are adequate as AC methods. The amplitude of the AC recovery could be overestimated using the uniform map. Therefore, application of a global attenuation factor on PET data might not be accurate for attenuation correction.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  7. [해외논문]   Visual Suppression is Impaired in Spinocerebellar Ataxia Type 6 but Preserved in Benign Paroxysmal Positional Vertigo  

    Kishi, Masahiko (Neurology, Internal Medicine, Sakura Medical Center, Toho University, Sakura, 564-1 Shimoshizu, Sakura 285-8741, Japan) , Sakakibara, Ryuji (E-Mails: neuro-mkishi@sakura.med.toho-u.ac.jp (M.K.)) , Yoshida, Tomoe (osirukooomori@yahoo.co.jp (Y.T.)) , Yamamoto, Masahiko (tateno@med.toho-u.ac.jp (A.T.)) , Suzuki, Mitsuya (f-tateno@sakura.med.toho-u.ac.jp (F.T.) ) , Kataoka, Manabu (Neurology, Internal Medicine, Sakura Medical Center, Toho University, Sakura, 564-1 Shimoshizu, Sakura 285-8741, Japan) , Tsuyusaki, Yohei (E-Mails: neuro-mkishi@sakura.med.toho-u.ac.jp (M.K.)) , Tateno, Akihiko (osirukooomori@yahoo.co.jp (Y.T.)) , Tateno, Fuyuki (tateno@med.toho-u.ac.jp (A.T.))
    Diagnostics v.2 no.4 ,pp. 52 - 56 , 2012 ,

    초록

    Positional vertigo is a common neurologic emergency and mostly the etiology is peripheral. However, central diseases may mimic peripheral positional vertigo at their initial presentation. We here describe the results of a visual suppression test in six patients with spinocerebellar ataxia type 6 (SCA6), a central positional vertigo, and nine patients with benign paroxysmal positional vertigo (BPPV), the major peripheral positional vertigo. As a result, the visual suppression value of both diseases differed significantly; e.g., 22.5% in SCA6 and 64.3% in BPPV (p

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  8. [해외논문]   Prenatal Diagnosis of Chromosome Abnormalities: A 13-Year Institution Experience  

    Comas, Carmen (Department of Obstetrics and Gynecology, Institut Dexeus, Fetal Medicine Unit., Gran Via Carles III, 71-75, 08028 Barcelona, Spain) , Echevarria, Mó (E-Mails: monech@dexeus.com (M.E.)) , nica (marrod@dexeus.com (M.A.R.)) , Rodrí (nacrod@dexeus.com (I.R.)) , guez, Marí (silnun@dexeus.com (B.S.) ) , a Á (Department of Obstetrics and Gynecology, Institut Dexeus, Fetal Medicine Unit., Gran Via Carles III, 71-75, 08028 Barcelona, Spain) , ngeles (E-Mails: monech@dexeus.com (M.E.)) , Rodrí (marrod@dexeus.com (M.A.R.)) , guez, Ignacio (nacrod@dexeus.com (I.R.)) , Serra, Bernat (silnun@dexeus.com (B.S.) ) , Cirigliano, Vincenzo (Department of Obstetrics and Gynecology, Institut Dexeus, Fetal Medicine Unit., Gran Via Carles III, 71-75, 08028 Barcelona, Spain)
    Diagnostics v.2 no.4 ,pp. 57 - 71 , 2012 ,

    초록

    Objective : To analyze trends in screening and invasive prenatal diagnosis of chromosome abnormalities (CA) over a 13-year period and correlate them to changes in the national prenatal screening policy. Methods : We retrospectively reviewed Down syndrome (DS) screening tests and fetal karyotypes obtained by prenatal invasive testing (IT) in our fetal medicine unit between January 1999 and December 2011. Results : A total of 24,226 prenatal screening tests for DS and 11,045 invasive procedures have been analyzed. Over a 13-year period, utilization of non-invasive screening methods has significantly increased from 57% to 89%. The percentage of invasive procedures has declined from 49% to 12%, although the percentage of IT performed for maternal anxiety has increased from 22% to 55%. The percentage of detected CA increased from 2.5% to 5.9%. Overall, 31 invasive procedures are needed to diagnose 1 abnormal case, being 23 procedures in medical indications and 241 procedures in non-medical indications. Conclusions : Our experience on screening and invasive prenatal diagnostic practice shows a decrease of the number of IT, with a parallel decline in medical indications. There is an increasing efficiency of prenatal screening program to detect CA. Despite the increasing screening policies, our population shows a growing request for prenatal IT. The a priori low risk population shows a not negligible residual risk for relevant CA. This observation challenges the current prenatal screening strategy focused on DS; showing that the residual risk is higher than the current cut-off used to indicate an invasive technique.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  9. [해외논문]   Gold Nanoparticles-Coated SU-8 for Sensitive Fluorescence-Based Detections of DNA  

    Cao, Cuong (DTU-NANOTECH, Department of Micro and Nanotechnology, Technical University of Denmark, DTU Building 423, DK-2800 Kongens Lyngby, Denmark) , Birtwell, Sam W. (Email: ccao@ntu.edu.sg (C.C.)) , Høgberg, Jonas (anders.wolff@nanotech.dtu.dk (A.W.) ) , Morgan, Hywel (School of Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK) , Wolff, Anders (Email: s.birtwell@soton.ac.uk (S.W.B.)) , Bang, Dang Duong (hm@ecs.soton.ac.uk (H.M.) )
    Diagnostics v.2 no.4 ,pp. 72 - 82 , 2012 ,

    초록

    SU-8 epoxy-based negative photoresist has been extensively employed as a structural material for fabrication of numerous biological microelectro-mechanical systems (Bio-MEMS) or lab-on-a-chip (LOC) devices. However, SU-8 has a high autofluorescence level that limits sensitivity of microdevices that use fluorescence as the predominant detection workhorse. Here, we show that deposition of a thin gold nanoparticles layer onto the SU-8 surface significantly reduces the autofluorescence of the coated SU-8 surface by as much as 81% compared to bare SU-8. Furthermore, DNA probes can easily be immobilized on the Au surface with high thermal stability. These improvements enabled sensitive DNA detection by simple DNA hybridization down to 1 nM (a two orders of magnitude improvement) or by solid-phase PCR with sub-picomolar sensitivity. The approach is simple and easy to perform, making it suitable for various Bio-MEMs and LOC devices that use SU-8 as a structural material.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지
  10. [해외논문]   Cell-Based Biosensors: Electrical Sensing in Microfluidic Devices  

    Kiilerich-Pedersen, Katrine , Rozlosnik, Noemi
    Diagnostics v.2 no.4 ,pp. 83 - 96 , 2012 ,

    초록

    Cell-based biosensors provide new horizons for medical diagnostics by adopting complex recognition elements such as mammalian cells in microfluidic devices that are simple, cost efficient and disposable. This combination renders possible a new range of applications in the fields of diagnostics and personalized medicine. The review looks at the most recent developments in cell-based biosensing microfluidic systems with electrical and electrochemical transduction, and relevance to medical diagnostics.

    원문보기

    원문보기
    무료다운로드 유료다운로드

    회원님의 원문열람 권한에 따라 열람이 불가능 할 수 있으며 권한이 없는 경우 해당 사이트의 정책에 따라 회원가입 및 유료구매가 필요할 수 있습니다.이동하는 사이트에서의 모든 정보이용은 NDSL과 무관합니다.

    NDSL에서는 해당 원문을 복사서비스하고 있습니다. 아래의 원문복사신청 또는 장바구니담기를 통하여 원문복사서비스 이용이 가능합니다.

    이미지

    Fig. 1 이미지

논문관련 이미지